English –
18
A.16 - Locking and unlocking the motor’s memory
NOTES AND WARNINGS
• Locking the motor’s memory stops any other (unscheduled or unauthorised) transmitters being memorised in it.
1
2
3
4
PRG
(x
1
)
2
PRG
(x
1
)
2
PRG
(x
1
)
3
Press and release
the button (
1 time
);
count 2 movements.
Press and release
the button (
1 time
);
count 2 movements.
Press and release
the button (
1 time
);
count 3 movements.
4
5
...
=
5
sec
4
Select one of the following potions and execute it:
• option A
– LOCK motor’s memory.
• option B
– UNLOCK motor’s memory.
Hold down both buttons...
release them after
5 sec-
onds
;
count 4 movements.
option –
A
5
end
option –
B
5
end
=
5
sec
3
=
5
sec
5
Hold down the but-
tonand
release it after
5
seconds
;
count 3 movements.
Hold down the but-
tonand
release it after
5
seconds
;
count 5 movements.
A
––– GROUP “B” PROCEDURES ––
Procedures run with the motor head buttons
B.1 - Precise adjustment of the UP (“0”) and DOWN (“1”) limit switch positions
NOTES AND WARNINGS
• This adjustment can be done at any time, on condition that the limit switch positions have already been programmed.
• The following procedure describes the setting of the Upper limit switch “0”.
To adjust the Lower limit switch “1”: (in step 1)
command a DOWN movement (rather
than UP);
(in step 2)
adjust the height of limit switch “1” (instead of the height of limit switch “0”);
(in step 3)
as in the figure below.
1
2
3
Command
an UP
movement
(x
1
)
“
0
”
Adjust the po-
sition of limit
switch “0”.
“
0
”
Press and release the key.
Wait for the move-
ment to finish at posi-
tion “0”.
Press the buttons until you reach the desired position.
Note
– Each step of the motor corresponds to a rotation
of around 2°.
3
end
=
5
sec
3
Hold down either of the two buttons;
release it after
5 seconds
;
count 3 movements.
B