English –
16
A.13 - Adjusting the acceleration (at the start of the awning movement) and deceleration
(towards the end of the movement)
NOTES AND WARNINGS
•
“Acceleration/deceleration” is expressed in roller rotations. This is the number of rotations of the roller the system requires to accelerate from the start of the move-
ment to the cruise speed. It also represents the number of rotations of the roller the system requires to decelerate from cruise speed to stopping at the limit switch.
•
The “nominal acceleration/deceleration” setting is the factory setting.
1
2
3
4
PRG
(x
1
)
2
PRG
(x
1
)
2
=
5
sec
3
Press and release
the button (
1 time
);
count 2 movements.
Press and release
the button (
1 time
);
count 2 movements.
Hold down the buttonand release it after
5
seconds
;
count 3 movements.
4
5
continues
=
5
sec
3
Select the
desired
option and
program it
as follows
(x
...
)
5 OPTIONS:
1 press
= sets
no acceleration/deceleration = 0 rotations
2 presses
= sets
brief acceleration/deceleration = 0.7 rotations
3 presses
= sets
nominal acceleration/deceleration = 1.5
rotations
4 presses
= sets
long acceleration/deceleration = 2 rotations
5 presses
= sets
maximum acceleration/deceleration = 3
rotations
Hold down the
buttonand
release it after
5
seconds
;
count 3 movements.
Press and release the button
the number of times
indicated in the option you have
chosen;
5
6
end
7
sec.
?
1
/
2
/
3
/
4
/
5
/
=
5
sec
3
After about 7 seconds, the motor performs a num-
ber of
movements
equal to the number of pulses
entered.
Hold down the buttonand
release it after
5 seconds
;
count 3 movements.
A
A.14 - Adjusting the total duration of the movement
NOTES AND WARNINGS
• This adjustment can only be done if the limit switches (“0” and “1”) have already been programmed.
•
The value set with this procedure, together with the “acceleration/deceleration” setting (procedure A.13) determines the cruise speed. To determine whether the re-
sulting cruise speed is compatible with the awning (weight, roller dimensions, torque), refer to “Technical characteristics”.
• The factory setting is disabled.
1
2
3
4
PRG
(x
1
)
2
PRG
(x
1
)
2
=
5
sec
3
Press and release
the button (1 tim
e
);
count 2 movements.
Press and release
the button (
1 time
);
count 2 movements.
Hold down the buttonand release it after
5
seconds
;
count 3 movements.
A
Содержание E EDGE XSI 0620 LDC
Страница 1: ...Tubular Motor EN Instructions and warnings for installation and use Nice E EDGE XSI 0620 LDC...