13
– English
4
5
...
PRG
(x
1
)
4
Select one of the following potions and execute it:
• option A
– delete the motor’s ENTIRE memory.
• option B
– delete ALL memorised transmitters.
• option C
– delete ONE memorised transmitter.
• option D
– delete ALL positions (“0”, “1”, “H”, etc.).
Caution!
– This deletion must be performed only when you want to
reprogram all the positions, using a different procedure than the one used previously (e.g. you have used manual distance
programming (A.3) and would now like to use the semi-automatic procedure (A.4).
Press and release
the button (
1 time
);
count 4 movements.
option –
A
5
end
option –
B
5
end
PRG
(x
1
)
5
=
5
sec
5
Press and release the
button (
1 time
);
count 5 movements.
Hold down the buttonand
release it after
5 seconds
;
count 5 movements.
option –
C
5
6
end
=
5
sec
3
=
5
sec
5
Hold down the but-
tonand
release it after
5
seconds
;
count 3 movements.
On the transmitter you wish to delete:
hold down
any button either the key memorised in mode 2 or the
climatic conditions sensor;
count 5 movements.
option –
D
5
end
=
5
sec
5
Hold down both buttons...
release them after
5
seconds
;
count 5 movements.
A.8.2 - Procedure run with a transmitter which has not yet been memorised
NOTES AND WARNINGS
• In order to carry out the following procedures, a transmitter with a PRG button should be used.
A.8.2.
A
- Procedure run with a transmitter which has not yet been memorised and cables for the voltage free contacts
1
2
3
4
...
OFF
ON
Run procedure
A.8.1 in full.
Disconnect the electrical
power supply to the motor.
Connect the
white
and
white-black
wires together
.
Reconnect the electrical pow-
er supply to the motor once
again.
A.8.2.
B
- Procedure run with a transmitter that has not yet been memorised and the limit switch adjustment buttons on the motor head
1
2
...
=
5
sec
when the light starts
flashing, you have
1
minutes
to complete
the procedure.
Run procedure
A.8.1 in full.
On the motor head:
hold down both
buttons and
release them after
5 seconds
;
the
red led
starts flashing (it turns off when the procedure is
completed).
Содержание E EDGE XSI 0620 LDC
Страница 1: ...Tubular Motor EN Instructions and warnings for installation and use Nice E EDGE XSI 0620 LDC...