Parameter:
3. LED diode indications
Description:
This parameter allows to set the actions which result in LED diode indications. This parameter does not apply to
the most important actions, such as CO Alarm, Malfunction Alarm and Low Battery Alarm.
Parameter 3 values may be combined, e.g. 1+2+4=7 means that all actions will be active.
Available settings:
0 - all actions disabled
1 - tampering (opened casing)
2 - exceeding the temperature
4 - lack of Z-Wave range
Default setting:
0
Parameter size:
1 [byte]
Parameter:
4. Acoustic signals
Description:
This parameter allows to set the actions which result in acoustic signals. This parameter does not apply to the
most important actions, such as CO Alarm, Malfunction Alarm and Low Battery Alarm.
Parameter 4 values may be combined, e.g. 1+2+4=7 means that all actions will be active.
Available settings:
0 - all actions disabled
1 - tampering (opened casing)
2 - exceeding the temperature
4 - lack of Z-Wave range
Default setting:
0
Parameter size:
1 [byte]
Parameter:
4. Acoustic signals
Description:
This parameter allows to set the actions which result in acoustic signals. This parameter does not apply to the
most important actions, such as CO Alarm, Malfunction Alarm and Low Battery Alarm.
Available settings:
0 - all actions disabled
1 - tampering (opened casing)
2 - exceeding the temperature
4 - lack of Z-Wave range
Default setting:
0
Parameter size:
1 [byte]
Parameter:
7. Associations in Z-Wave network security mode
Description:
Parameter defines how commands are sent in specified association groups: as secure or non-secure. Parameter
is active only in Z-Wave network security mode. It does not apply to 1st “Lifeline” association group.
Parameter 7 values may be combined, e.g. 1+2=3 means that 2nd & 3rd group are sent as secure.
Available settings:
1 - 2nd group sent as secure
2 - 3rd group sent as secure
4 - 4th group sent as secure
8 - 5th group sent as secure
16 - 6th group sent as secure
32 - 7th group sent as secure
Default setting:
63
Parameter size:
1 [byte]
Parameter:
10. Commands sent to 2nd association group (CO Alarm)
Description:
This parameter defines commands sent to devices associated in 2nd association group (CO Alarm). Values of
specified commands may be set in parameters 11 and 12.
Available settings:
1 - BASIC ON
2 - BASIC OFF
3 - BASIC ON & BASIC OFF
Default setting:
3 (ON & OFF)
Parameter size:
1 [byte]
Parameter:
11. Value of BASIC ON command sent to 2nd association group
Description:
This parameter defines the value of BASIC ON command sent to devices in 2nd association group after the CO
Alarm activation.
Available settings:
0-99 or 255
Default setting:
255 (turn on)
Parameter size:
2 [bytes]
Parameter:
12. Value of BASIC OFF command sent to 2nd association group
Description:
This parameter defines the value of BASIC OFF command sent to devices in 2nd association group after the CO
Alarm cancellation.
Available settings:
0-99 or 255
Default setting:
0 (turn off)
Parameter size:
2 [bytes]