Service menus
45
SMO 10
Quick start
Operating settings
Alarm log
Menu 9.5.0 Alarmlog
The alarm logs are shown in the sub-menus of this
menu.
A l a r m l o g
9 . 5 . 0
Menu 9.6 Return
Pressing the Enter button returns you to menu 9.0.
R e t u r n
9 . 5 . 5
Menu 9.5.5 Return
Pressing the Enter button returns you to menu 9.5.0
R e t u r n
9 . 6
S
Menu 9.4 Quick start
Both SMO 10 and FIGHTER 2010 / 2005 start within 3
minutes.
N o
Q u i c k s t a r t
9 . 4
S
Menu 9.3.14 Return
Pressing the Enter button returns you to menu 9.3.0.
R e t u r n
9 . 3 . 1 6
Menu 9.3.10 Flow diff HP
When the current flow temperature
deviates
from the
set value compared to that calculated, the heat pump
is forced to stop/ irrespective of the degree-minute fig-
ure.
When the current flow temperature
exceeds
the set
value, the degree-minute figure is set to 1. The com-
pressor stops when there is only a heating require-
ment.
When current flow temperature
falls below
the set
value, the degree-minute figure is set to -60. This
means the compressor will start. When the value also
falls below menu (9.3.11), the degree-minute figure
can be set to -400. The value is adjustable between 3
and 25 °C.
1 0 ° C
F l o w d i f f H P
9 . 3 . 1 0
S
Menu 9.3.11 Diff HP Add
When the current flow temperature drops below that cal-
culated by the set value plus the value from menu 9.3.10
the degree-minute value is set to -400. This means that
the additional heat can be engaged directly. The value is
adjustable between 1 and 8 °C.
3 ° C
D i f f H P A d d
9 . 3 . 1 1
S
Menu 9.3.12 Warmvater recyc.time
The hot water's circulation time is set here. Stated in
increments of 30 minutes. The value is adjustable
between 0 and 30 minutes.
1 m i n
W a r m v a t e r r e c y c . t i m e
9 . 3 . 1 2
S
Menu 9.3.13 Block HW/Heating
When there is no need of hot water or heating these
settings can be made here.
No HW, No heating or HW+Heating.
H W + H e a t i n g
B l o c k H W / H e a t i n g
9 . 3 . 1 3
S
Menu 9.3.14 Heat drop at alarm
When Yes is selected, attention is attracted to a
tripped alarm through the flow temperature being low-
ered to Min.temp. flow.
When No is selected, the flow temperature is not low-
ered in the event of an alarm. This means that regular
inspection of SMO 10 is necessary. When clearer
alarm indication is desired, for example a lamp or a
buzzer, SMO 10's extra alarm output is used, see
Electrical connections — Alarm/alarm outputs.
Ye s
H e a t d r o p a t a l a r m
9 . 3 . 1 4
S
Menu 9.3.15 Let SMO select step
When NO is selected, FIGHTER 2010 changes power
step according to the outdoor temperature, the value
is set in menu 9.1.7. When Yes is selected Yes, SMO
10 automatically switches between step A and B to
handle the heating requirement. (No function for
FIGHTER 2005.)
N o
L e t S M O s e l e c t s t e p
9 . 3 . 1 5
S
Содержание SMO 10
Страница 1: ...R MOS GB 0521 1 511262 SMO 10 INSTALLATION AND MAINTENANCE INSTRUCTION SMO 10...
Страница 2: ......
Страница 50: ...Electrical circuit diagram 48 SMO 10 Sheet 1 4...
Страница 54: ...Dimensions 52 SMO 10 405 406 151 5 328 276 Dimensions and setting out coordinates...
Страница 58: ...SMO 10 56...
Страница 59: ......