INSTALLATION AND MAINTENANCE INSTRUCTION

SMO 10

Содержание SMO 10

Страница 1: ...R MOS GB 0521 1 511262 SMO 10 INSTALLATION AND MAINTENANCE INSTRUCTION SMO 10...

Страница 2: ......

Страница 3: ...erature 18 Connecting the outside sensor 18 Centralised load control and load monitor 19 External contacts 20 Alarm alarm outputs 20 Docking General 21 FIGHTER 2010 2005 docked to an oil fired pellet...

Страница 4: ...p Curve slope setting Offset heating curve setting Date__________________ Signed_____________________ Completed when the product is installed In order to get the ultimate benefit from your SMO 10 you...

Страница 5: ...line diagram is equipped with accessories VXV1 PG SMO 10 HR HR HR HR HR P FIGHTER 2010 FG1 CP1 RG1 RG2 SV1 SV2 CP2 FG2 VVC VVG LP1 UG RG FG AV S V TV RV SF S V SMO 10 is an advanced control module tha...

Страница 6: ...ted The line indicates which power step steps are currently connected Only shown when the immersion heater is connected Power step I is connected Power step II is connected Power step III is connected...

Страница 7: ...immersion heater is connected The current operating mode is shown on the display when the button is pressed and the mode changes when you continue to press the button The display returns to the normal...

Страница 8: ...settings use the basic data from the map opposite If the required room temperature is not obtained read justment may be necessary NOTE Wait one day between settings so that the tem peratures have time...

Страница 9: ...ly set temperature turn the Heating curve offset knob anticlockwise or clockwise One to three lines approxi mately represents a 1 degree change in room tempera ture NOTE An increase in the room temper...

Страница 10: ...1 10 9 8 7 6 5 4 3 2 1 V RMEKURVA 5 5 F RSKJUTNING V RMEKURVA 0 15 14 13 12 11 10 9 8 7 6 5 4 3 2 1 40 C UTETEMPERATUR 10 0 10 5 5 30 40 50 60 70 C FRAMLEDNINGSTEMPERATUR 20 30 F RSKJUTNING V RMEKURVA...

Страница 11: ...setting the miniature circuit breakers Tripped temperature limiter Contact service Load monitor or external control may have blocked the electrical output Incorrect values set for hot water production...

Страница 12: ...ck ground lighting flashes The following information can be shown L O W F L U I D T E M P 1 0 High Pressure This information is shown when the high pressure switch in FIGHTER 2010 2005 has tripped Thi...

Страница 13: ...due to a faulty sensors or broken sensor cable The information disappears once the fault has been rectified and the alarm reset on menu 9 3 6 WARMWATER ALARM 1 0 S U P P L Y S E N S O R 1 0 Warmwater...

Страница 14: ...hould be documented The above applies to installations with a closed expansion vessel If the electric boiler or the expansion vessel is replaced the installation must be inspected again Inspection of...

Страница 15: ...alified electrician Electrical installation and wiring must be carried out in accordance with the stipulations in force NOTE In order to prevent operating disturbances sensor cables and modular cables...

Страница 16: ...he Installation and Maintenance Instruction Routing of the modular cable in FIGHTER 2010 2005 should be done from below in the cable glands on left hand side of the heat pump seen from the front LEK 4...

Страница 17: ...sition 44 and FIGHTER 2010 2005 VP3 position 44 Routing of the cable in FIGHTER 2010 2005 should be done from below in the cable glands on left hand side of the heat pump seen from the front LEK 44 FI...

Страница 18: ...Re11 Re12 Re13 Re14 L N Laddpump F 2010 VXV 1 Shunt1 L1 N CP1 CP2 TS2 TS1 TS3 N VV VVC Shunt2 N N N N N N Opto Opto Opto Opto SMO 10 Externt N L1 L1 Pool styrning Pool L1 VXV 2 Pool VV S N 230V L1 N...

Страница 19: ...ol G UG 57 58 59 60 Fas1 Fas3 Fas2 The suppressor supplied in the enclosed kit should be fitted either to terminal 11 or on the connector NOTE In order to prevent operating disturbances sensor cables...

Страница 20: ...nary The setting of the different maximum immersion heater outputs is done using the knob 101 on the load monitor card 2 The setting of the different maximum boiler hot water heater temperatures is do...

Страница 21: ...d monitor SMO 10 is equipped with an internal load monitor When the load monitor senses an overcurrent on one of the phases the immersion heater will step down the output until it can be connected aga...

Страница 22: ...s tripped Indicated as LP ALARM 05 SMO 10 switches to additional mode High pressure pressostat HP in FIGHTER 2010 2005 has tripped Indicated as HP ALARM 06 SMO 10 switches to additional mode Motor cut...

Страница 23: ...V1 VVC VVG LP1 UG S V SMO 10 controls FIGHTER 2010 2005 oil fired boil er circulation pumps shunts etc FIGHTER 2010 2005 works with floating condensing against the heat ing system and prioritizes hot...

Страница 24: ...s with floating condensing against the heating system and pri oritizes hot water charging via the shuttle valve VXV1 FIGHTER 2010 2005 works in stage 1 or stage 2 depending on the outdoor air temperat...

Страница 25: ...ng via the shut tle valve VXV1 FIGHTER 2010 2005 works in stage 1 or stage 2 depending on the outdoor air temperature and the heating requirement FIGHTER 2010 2005 VP1 heats hot water If FIGHTER 2010...

Страница 26: ...intain the heating requirement the shunt valve SV1 starts to open towards FIGHTER 310 This means FIGHTER 310 now works as an addi tional heater Function SMO 10 controls FIGHTER 2010 2005 immersion hea...

Страница 27: ...anged in SMO 10 When more than one FIGHTER 2010 2005 is connected they all receive the same values Channel 13 should be set to 2 Confirm with the Enter button Select Service in menu 8 1 1 Menu type Se...

Страница 28: ...formation is presented on the display about the status of the heat pump and the electric boiler Menu 1 0 is nor mally shown on the display screen The Plus and Minus buttons and the Enter button are us...

Страница 29: ...External adjustment 2 6 0 Own Curve Definition 2 7 Return temperature 2 8 Degree Minutes 2 9 Return 2 0 2 6 1 Supply Temp at 20 C 2 6 2 Supply Temp at 20 C 2 6 3 Set temperature 2 6 4 Flow temp at se...

Страница 30: ...tra HW Sunday 7 4 8 Return 7 4 0 8 1 0 Display settings 8 2 0 Operating mode 8 3 0 Current limiter 8 4 0 Pool Control 8 5 Return 8 0 8 0 Other Adjustments 8 2 1 Summertemp 8 2 2 Wintertemp 8 2 3 Retur...

Страница 31: ...sent 9 3 4 Room unit 9 3 5 0 Floor drying 9 3 6 Remove alarms 9 3 7 Factory setting 9 3 8 0 Testmode 9 3 9 Operating mode 9 3 10 Flow diff HP 9 3 11 Diff HP Add 9 3 12 Warmvater recyc time 9 3 5 1 Flo...

Страница 32: ...monitor reading are made in the sub menus to this menu Menu 9 0 Service menus This menu and its submenus are only shown on the display screen when access has been selected in menu 8 1 1 Values can be...

Страница 33: ...mal level to the extra hot water level is shown here The value is adjustable between 0 and 90 days Extra hot water is shutoff when 0 is set Extra hot water starts when the value has been confirmed Men...

Страница 34: ...een 0 and 80 C Menu 2 6 2 Supply temp at 20 C The flow temperature at an outside temperature of 20 is chosen here The value is adjustable between 0 and 80 C Menu 2 6 3 Set temperature Here you select...

Страница 35: ...emp at set You set the required flow temperature for the break point here The value is adjustable between curves 0 and 80 C 2 0 C F l o w t e m p a t s e t 2 6 4 R e t u r n 4 2 Menu 2 9 Return Pressi...

Страница 36: ...t mode only FIGHTER 2010 C o m p r e s s o r s t a t u s 1 5 3 Menu 5 4 Minutes to start The time to compressor start in FIGHTER 2010 2005 is shown in this menu M i n u t e s t o s t a r t 1 5 4 Menu...

Страница 37: ...r n 5 1 7 Menu 5 13 Hotgas temperature In this menu the hot gas temperature in FIGHTER 2010 2005 is shown 7 8 C H o t g a s t e m p e r a t u r e 1 5 1 3 U Menu 5 16 Start defrosting Manual activatio...

Страница 38: ...turns you to menu 7 3 R e t u r n 7 3 3 Menu 7 2 Time Here the current time is set 1 3 3 9 T i m e 7 2 Time and Date Menu 7 4 0 Extra hot water Settings are made in the sub menus of this menu when ext...

Страница 39: ...s p l a y s e t t i n g s 8 1 0 Menu 8 1 1 Menu Type The menu type is chosen here Normal extended or service Normal covers the normal user s needs Extended shows all menus except the ser vice menus S...

Страница 40: ...d monitor card 2 is shown here knob 100 1 6 A F u s e s i z e 8 3 1 Menu 8 3 3 Current Phase 1 Shows the measured current from phase 1 3 5 A C u r r e n t P h a s e 1 8 3 3 Menu 8 3 4 Current Phase 2...

Страница 41: ...temperature when the pool heating should start is set here state in whole C When the temperature falls below this value pool heating starts once the hot water and heating requirement have been met The...

Страница 42: ...e is adjustable between 5 and 12 minutes 7 m i n M a x d e f r o s t t i m e 0 9 9 1 5 Menu 9 1 7 Powerstepup Outdoor air temperature to change the power step in FIGHTER 2010 The value is adjustable b...

Страница 43: ...s in brackets denote the corresponding channel number in FIGHTER 2010 2005 S S S S Menu 9 1 15 Comp Stop XVV The temperature at which with extra hot water the compressor operations switch to the immer...

Страница 44: ...tor time The number of degree minutes that run per step after additional heat has been engaged is set here The value is adjustable between 10 and 100 degree minutes 1 0 0 I n t e g r a t o r t i m e 9...

Страница 45: ...menus in this menu O p e r a t i n g s e t t i n g s 9 3 0 Menu 9 3 1 Max Boilertemp The setting selected on the load monitor card 2 knob 102 is shown here 8 0 C M a x B o i l e r t e m p 9 3 1 S S Me...

Страница 46: ...3 5 1 Floor drying This sub menu is used to select whether the floor dry ing program should be On or Off After time period 1 switching to time period 2 then return to normal set tings O f f F l o o r...

Страница 47: ...culated by the set value plus the value from menu 9 3 10 the degree minute value is set to 400 This means that the additional heat can be engaged directly The value is adjustable between 1 and 8 C 3 C...

Страница 48: ...Component placement 46 SMO 10 LEK 14 100 101 30 18 25 38 32 102 7 11 8 2 34 29 4 33 32 103 66 Hotwatertemperature...

Страница 49: ...fuse concealed on relay card 34 Central unit 38 Knob Offset heating curve 66 Rating plate 100 Knob Fuse setting 101 Knob Max electrical output setting 102 Knob Max boiler temperature setting 103 Seri...

Страница 50: ...Electrical circuit diagram 48 SMO 10 Sheet 1 4...

Страница 51: ...Electrical circuit diagram 49 SMO 10 Sheet 2 4 Not supplied with SMO 10 Charge pump Shuttle valve Pool Pool control Charge pump Shuttle valve...

Страница 52: ...Electrical circuit diagram 50 SMO 10 Sheet 3 4 Not supplied with SMO 10 Addition 2 Addition 1 Addition 3 Immersion heater hot water...

Страница 53: ...t 4 4 Return 2 Flow 2 Boiler Hot water Return 1 Flow 1 Pool Current transformer L3 Current transformer L2 Current transformer L1 Centralised load control 1 1 Centralised load control 1 2 External comp...

Страница 54: ...Dimensions 52 SMO 10 405 406 151 5 328 276 Dimensions and setting out coordinates...

Страница 55: ...VPA 300 200 Part no 088 141 VPA 450 150 Part no 088 153 Hot water control VST 11 Part no 089 152 Reversing valve Cu pipe 28 Max recommended charge power 15 kW Modular cable LEK Modular cable 15 m wit...

Страница 56: ...tur givare Ou tdo or tem perature sensor Aussentem peratur f h ler Artikel 018764 Outdoor sensor UG Temperature sensor with pin LEK Modular cable 15 m Aluminium tape LEK AJ LEK LEK LEK LEK Heating pip...

Страница 57: ...number of sensor 14 Max number of circulation pumps heating system 2 Enclosure class IP21 Width 363 mm Depth 156 mm Max number of FIGHTER 2010 2005 9 Max number of charge pumps 1 Supply voltage 230 V...

Страница 58: ...SMO 10 56...

Страница 59: ......

Страница 60: ...mtechnik GmbH Am Reiherpfahl 3 29223 Celle Tel 05141 7546 0 Fax 05141 7546 99 E mail info nibe de www nibe de NIBE Energietechniek B V Postbus 2 4797 ZG WILLEMSTAD NB Tel 0168 477722 Fax 0168 476998 E...