NIBE VVM 300
Miscellaneous
9.3.0 Operating settings
Settings regarding additional heat, floor drying and a re-
turn to the factory settings can be made on the sub-menus
in this menu.
Menu 9.3.1 Max. boiler temp.
The setting selected on the EBV card (2) knob (102) is
shown here.
Menu 9.3.2 Add. heat mode
Additional heat mode is activated when “Yes” is shown
on the display screen, otherwise “No” is shown. When the
additional heat mode is activated, the immersion heater
respective circulation pump cannot be blocked with the
operating mode button.
Menu 9.3.3 Shunt 2
Shunt group 2 can be set to “On” or “Off” here (accesso-
ries required).
Menu 9.3.4 Room unit
Accessories are needed.
Menu 9.3.5 Room sensor
A room sensor is reset here if installed (accessory RG05
required).
Menu 9.3.6 Reset alarm
Resetting alarms in VVM 300.
Menu 9.3.7 Clear alarm log
Clearing the alarm log in VVM 300.
Menu 9.3.8.0 Test mode
Only for service personnel.
Menu 9.3.9 Factory setting
Return to the factory settings in VVM 300, “Yes” or “No”.
Menu 9.3.10 Operating mode
Describes the operating status of VVM 300 and the air/wa-
ter heat pump.
Shutdown:
Additional heater and heat pump are shut-
down due to an alarm.
Alternating:
The heat pump produces heat and switches,
when necessary, between hot water and heating.
Combined Mode:
Due to a great heating demand, the
immersion heater is used for hot water and the heat pump
produces heat. The addition assists, when necessary, with
heat production.
Hot water:
Only hot water is produced. This is carried out
by the heat pump.
Addition:
The heat pump is off and both hot water and
heat is produced by the addition.
Menu 9.3.11.0 Floor drying setting
Settings for the floor drying program are made in the sub-
menus to this menu.
Menu 9.3.11.1 Floor drying
“On” or “Off” is selected for the floor drying program
from this sub-menu. After time period 1 a switch is made
to time period 2 followed by a return to the normal set-
tings.
Menu 9.3.11.2 Period time 1
Selection of the number of days in period 1. The value is
adjustable between 1 and 5 days. The factory setting is 3
days.
Menu 9.3.11.3 Temperat. period 1
Selection of the flow temperature in period 1. The value is
adjustable between 15 and 50 °C. Factory setting is 25 °C.
Menu 9.3.11.4 Period time 2
Selection of the number of days in period 2. The value is
adjustable between 1 to 5. The factory setting is 1 days.
Menu 9.3.11.5 Temperat. period 2
Selection of the flow temperature in period 2. The value is
adjustable between 15 and 50 °C. Factory setting is 40 °C.
Menu 9.3.11.6 Return
Return to menu 9.3.11.0.
Menu explanation
Содержание NIBE VVM 300
Страница 2: ...LEK LEK 1 2 LEK LEK 3 4 5...
Страница 46: ...44 NIBE VVM 300 Miscellaneous Electrical circuit diagram Electrical circuit diagram...
Страница 47: ...45 NIBE VVM 300 Miscellaneous Electrical circuit diagram...
Страница 48: ...46 NIBE VVM 300 Miscellaneous Electrical circuit diagram...
Страница 49: ...47 NIBE VVM 300 Miscellaneous Electrical circuit diagram...
Страница 50: ...48 NIBE VVM 300 Miscellaneous Electrical circuit diagram...
Страница 57: ...55 NIBE VVM 300...
Страница 58: ...56 NIBE VVM 300...
Страница 59: ......