33
NIBE VVM 300
Miscellaneous
Menu 1.1 Start temperature HW
The temperature when the heat pump starts to work with
the hot water heater is set here.
The value can be set between 25 and 50 °C. The factory
setting is 45 °C.
Menu 1.2 Stop temperature HW
The temperature when the heat pump/immersion heater
should stop heating the water is set here.
The value can be set between 30 and 80 °C.
The factory setting is 50 °C.
Menu 1.3 Stop temp. XHW
The desired stop temperature for extra hot water is set
here.
The value can be set between 40 and 80 °C. The factory
setting is 65 °C.
Menu 1.4 Interval XHW
How often the hot water temperature is increased from
the normal level to the “Extra hot water” level is shown
here.
The value is adjustable between 0 and 90 days. Periodic
Extra hot water is
shut-off
at value
0
. Extra hot water is
started when the value is confirmed. The factory setting is
14 days.
Menu 1.5 Next XHW action
Future increases to the “Extra hot water” level are shown
here.
Menu 1.6 HW run time
How long hot water heating has been in progress is shown
here (accumulated).
Menu 1.7 Return
Return to menu 1.0.
1.0 Hot water temp.
Menu explanation
Содержание NIBE VVM 300
Страница 2: ...LEK LEK 1 2 LEK LEK 3 4 5...
Страница 46: ...44 NIBE VVM 300 Miscellaneous Electrical circuit diagram Electrical circuit diagram...
Страница 47: ...45 NIBE VVM 300 Miscellaneous Electrical circuit diagram...
Страница 48: ...46 NIBE VVM 300 Miscellaneous Electrical circuit diagram...
Страница 49: ...47 NIBE VVM 300 Miscellaneous Electrical circuit diagram...
Страница 50: ...48 NIBE VVM 300 Miscellaneous Electrical circuit diagram...
Страница 57: ...55 NIBE VVM 300...
Страница 58: ...56 NIBE VVM 300...
Страница 59: ......