Menu 8.1.0 Display settings
Settings concerning language and menu type are set on
the sub-menus to this menu.
Menu 8.1.1 Menu type
The menu type is chosen here: Normal, extended or serv-
ice.
Normal
, covers the normal user's needs.
Extended
, shows all menus except the service
menus.
Service
, shows all menus, returns to normal 30 min-
utes after the last button was pressed.
Menu 8.1.2 Language
The desired language is chosen here:
Menu 8.1.3 Display contrast
The display's contrast is set here. The value can be set be-
tween 0 and 31. The factory setting is 20.
Menu 8.1.4 Light intensity
The light intensity in idle mode is set here. Idle mode starts
30 minutes after the last button was pushed. The value is
adjustable between 0 and 2.
0=shut-off, 1=low, 2=average.
The factory setting is 2.
Menu 8.1.5 Return
Return to menu 8.1.0.
Menu 8.2.0 Auto mode settings
Settings regarding auto mode can be made in the sub-
menus to this menu.
Menu 8.2.1 Summertemp.
The average temperature when the circulation pump and
immersion heater are blocked is shown here.
The value can be set between 0 and 30 °C. The factory set-
ting is 25 °C.
8.0 Other adjustments
N
U
S
Menu 8.2.2 Wintertemp
The average temperature when the circulation pump and
immersion heater are activated is shown here.
The value can be set between 0 and 30 °C. The factory set-
ting is 20 °C.
Menu 8.2.3 Return
Return to menu 8.2.0.
Menu 8.3.0 Current limiter
Settings and readings regarding the load monitor are set
on the sub-menus to this menu.
Menu 8.3.1 Fuse size
The setting selected on the load monitor card (2) is shown
here knob (100).
Menu 8.3.2 Max. electric power
The setting selected on the load monitor card (2) is shown
here knob (101).
Menu 8.3.3 – 8.3.5 Current phase 1 – 3
Shows the measured current from phase 1 – 3.
Menu 8.3.6 Tranform. ratio EBV
The transfer value must be defined depending on the cur-
rent transformers used for the EBV card. This is done in this
menu. The value is adjustable between 100 and 1250 in
increments of 10. The setting 300 applies for the supplied
current transformers.
Menu 8.3.7 Return
Return to menu 8.3.0.
Menu 8.4.0 Pool settings
Pool settings are made on the sub-menus to this menu.
Menu 8.4.1 Pool control
You choose here whether pool control should be On or
Off.
Menu explanation
Содержание NIBE VVM 300
Страница 2: ...LEK LEK 1 2 LEK LEK 3 4 5...
Страница 46: ...44 NIBE VVM 300 Miscellaneous Electrical circuit diagram Electrical circuit diagram...
Страница 47: ...45 NIBE VVM 300 Miscellaneous Electrical circuit diagram...
Страница 48: ...46 NIBE VVM 300 Miscellaneous Electrical circuit diagram...
Страница 49: ...47 NIBE VVM 300 Miscellaneous Electrical circuit diagram...
Страница 50: ...48 NIBE VVM 300 Miscellaneous Electrical circuit diagram...
Страница 57: ...55 NIBE VVM 300...
Страница 58: ...56 NIBE VVM 300...
Страница 59: ......