Measure the height on the rear panel at which a hole must 
be made to connect the stove to the chimney. Cut away 
one or more of the panels in the telescopic mantle as 
required and hang the rear panel over the connecting flue. 
Then connect the stove to the chimney as described in the 
section headed “High-level elbow-joint flue connection”.

Screw the threaded pins into the upper flange of the chimney mantle. Then attach the sealing plate and lay the insulation 
in place as shown. The sealing plate and insulation are not used when connecting to a rear flue directly from the rear of the 
stove, nor when connecting to a top flue through the ceiling using the Premodul chimney system.

The telescopic mantle can be used with all types of flue 
connections described earlier in these instructions. The 
procedure below describes installation together with a high-
level elbow joint flue connection.

Installing a telescopic chimney mantle

Mutter M6

Gängad stång

Pannkitt

Pannkitt

GB

Heat-resistant sealant

Heat-resistant sealant

Nut M6

Threaded pin

Содержание handol 24

Страница 1: ...Installation Instruction 511295 IAV SE EX 0542 2 Handöl 24 Installationsanvisning 2 Installationsanleitung 14 Installasjonsanvisning 28 Installation Instructions 42 SE DE NO GB ...

Страница 2: ...nsion mantle 54 Dear Handöl owner May we take this opportunity to wish you a warm welcome to the Handöl family We hope your new stove will bring you much pleasure over the years Your choice is testimony to the high standards you demand in terms of lasting quality and enduring design You can rest assured that your new Handöl stove will serve you well and continue to grace your home for many years t...

Страница 3: ...radiated through the glass door Do not place combustible material closer than the recommended safe distances Failure to observe these safe distances can result in an uncontrolled fire A smouldering fire can cause gases and fumes to ignite without warning with the risk of causing damage to both persons and property IMPORTANT Always contact your local authority planning office before installing a wo...

Страница 4: ...gth of up to 1 0 metre is permissible provided that the vertical flue is at least 5 0 metres in height It must be possible to clean the flue throughout its entire length and the soot hatches must be easily accessible General information This folder contains assembly and installation instructions for Handöl 24 stoves You will also have received separate Lighting and Operating Instructions with your...

Страница 5: ...30 Brandmur av tegel eller betong 50 300 590 600 90 350 1490 2150 min 2200 Förbränningsluftsslang tillbehör Brännbart tak C 180 325 455 490 B 1 1105 70 D 520 1665 A 1190 B 2 1825 105 2150 A height from floor to top flue connection B1 height from floor to rear flue connection c c B2 c c height from floor to rear flue connection high level elbow joint C distance from back to top flue c c D height fr...

Страница 6: ...all behind the stove the punched metal plate in the rear panel of the stove must be knocked out with a hammer to allow the air supply hose to pass through The connecting collar on the fire box has an external diameter of 64 mm To prevent condensation in air ducts that pass through heated spaces the duct must be insulated with 30 mm of mineral wool covered with a moisture seal plastic vapour barrie...

Страница 7: ...into place as shown in the illustration Fitting a cast iron and aluminium mantelshelf optional accessory Unscrew the two socket head screws at the front edge of the top of the fire box Lay the cast iron mantelshelf support in place and secure it with four socket head screws The cast iron mantelshelf is fitted with four adjustable screws 8 mm Adjust the height of these screws so that the aluminium ...

Страница 8: ...ion from the top of the stove and knock out the punched metal plate on the rear of the stove Replace the flue collar with the covering cap and vice versa Then re fit the covering plates and insulation on the top of the stove as shown below Slide the connecting flue into the collar taking care to make sure that the gasket is not moved out of position Stand the stove on the floor plate and slide the c...

Страница 9: ...y ready for rear flue installation Lift off the sealing plate insulation and insulation retainer cut out the punched plate in the insulation retainer and remove the centre piece of the insulation The follow sequence describes the installation procedure for connecting the stove to the Premodul chimney system Fit the start section of the flue the flue base to the connecting collar Make sure that the ...

Страница 10: ...eiling insulation leaving a gap of 5 mm between the insulation and the chimney mantle Start with the rear section Make sure that the insulation is pushed up so it is touching the ceiling Press the rubber sealing strip into the gap around the chimney mantle Turn the sealing strip as shown in the illustration above Important The installation must be approved by a qualified inspector before the stove...

Страница 11: ...ation Fit the start section of the flue the flue base to the connecting collar Make sure that the packing round the collar is not moved from its intended position Then replace the insulation retainer the insulation and the sealing plate Secure the sealing plate in place against the stove hood by using pliers to bend the lugs on the hood Install the flue sleeve in the wall as described in the ins tr...

Страница 12: ... by lowering it onto the locating pins on the sealing plate Then fix the rear panel to the mantle Finally lay the covering plate on top Pannkitt Pannkitt Important The installation must be approved by a qualified inspector before the stove is made ready for use Read through the lighting and operating instructions for the Handöl 20 series carefully before lighting the stove for the first time GB He...

Страница 13: ...h the sealing plate and lay the insulation in place as shown The sealing plate and insulation are not used when connecting to a rear flue directly from the rear of the stove nor when connecting to a top flue through the ceiling using the Premodul chimney system The telescopic mantle can be used with all types of flue connections described earlier in these instructions The procedure below describes...

Страница 14: ...te is required between two chimney mantle sections Place the coupling plate on the lower of the mantles so that the threaded pins pass through the flange around the top inside edge of the mantle Fit the upper mantle section over the pins in a similar fashion Then fit rear panels to each section of the mantle HK Important The installation must be approved by a qualified inspector before the stove is ...

Страница 15: ...NIBE AB NIBE Brasvärme Box 134 285 23 Markaryd www nibe se ...

Отзывы: