Menu 1.1 Periodtime HW/Total
The time of the hot water period and the time for the
whole period are shown here.
Menu 1.3 MAX-time HW-period
The time (menu 1.1) that the hot water should be heat-
ed in each period is selected here. The value is
adjustable between 5 and 60.
Hot water temperature
Menu 1.4 HW-temp/Starttemp.HW
The temperature when the heat pump starts to work
with the hot water heater is set here. The value is
adjustable between 25 and 50.
Menu 1.5 HW-temp/Stoptemp.HW
The temperature when the heat pump/immersion
heater should stop heating the water is set here. The
value is adjustable between 30 and 80.
Menu 1.8 Interval XHW
How often the hot water temperature is increased from
the normal level to the extra hot water level is shown
here. The time is adjustable between 0 and 90 days.
Extra hot water is shutoff when 0 is set. Extra hot
water starts when the value has been confirmed.
Menu 1.9 Next XHW action
Future increases to the extra hot water level are
shown here.
Menu 1.10 HW running time
How long hot water heating has been in progress is
shown here
(accumulated).
2 0 ( 6 0 ) m i n
P e r i o d t i m e H W / T o t a l
1 . 1
1 4 d a y s
I n t e r v a l X H W
1 . 8
9 0 h 1 0 m i n
H W r u n n i n g t i m e
1 . 1 0
2 0 m i n
M A X - t i m e H W - p e r i o d
1 . 3
5 0 . 0 ( 4 7 ) ° C
H W - t e m p / S t a r t t e m p . H W
1 . 4
5 0 . 0 ( 5 4 ) ° C
H W - t e m p / S t o p t e m p . H W
1 . 5
Menu 1.6 Stop Temp. XHW
The required stop temperature for extra hot water is
set here. The value is adjustable between 40 and 70.
5 0 . 0 ( 6 0 ) ° C
S t o p T e m p . X H W
1 . 6
1 0 - 2 6 1 0 : 3 1
N e x t X H W a c t i o n
1 . 9
N
N
N
N
Menu 1.2 Time period
The length of time is set here. The value is adjustable
between 5 and 60.
6 0 m i n
T i m e p e r i o d
1 . 2
N
U
U
Menu 1.7 Stop compressor XHW
The temperature to stop the compressor for extra hot
water is set here. The value is adjustable between 50
and 58.
5 0 . 0 ( 5 6 ) ° C
S t o p c o m p r e s s o r X H W
1 . 7
U
U
U
Menu 1.11.0 Pool settings
Pool settings are made on the submenus to this
menu.
P o o l s e t t i n g s
1 . 1 1 . 0
Menu 1.11.1 Pooltemp./Setting
The temperature when pool heating is stopped is stat-
ed here.
The value is adjustable between 15 and 35°C.
1 9 . 0 ( 2 0 ) ° C
P o o l t e m p . / S e t t i n g
1 . 1 1 . 1
U