Actions with operating disturbances
43
For the Installer
FIGHTER 1220
NOTE!
The
product’s serial number
should always be stated with all
correspondence with NIBE.
689_ _ _ _ _ _ _ _ _ _ _
Close the shut-off valves in heating medium system.
Now open the drain valve (76). A small amount of
water runs out, however, to fully empty the heating
medium side requires the connector that joins the
heating medium side and the connection on the heat
pump HM-Flow to be loosened a little to allow air to
enter so the remaining water can run out. When the
heating medium is empty the requisite service can be
carried out.
When replacing the brine pump or drive side or when
cleaning the pump, the shut-off valves in the collector
system should be closed. The hose between the top
of the evaporator and the brine pump is loosened on
the evaporator. The loose hose end can now be bent
down and emptied in a small bowl. Now loosen the
connection on Brine in a little to allow air to enter so
the heat pump’s collector side is emptied completely.
When the circuit is empty the requisite service can be
carried out.
Draining, heat medium side
Draining, brine side
■
Shut down FIGHTER 1220 by turning the switch
(8) to 0.
■
Open the service cover.
■
Loosen the air screw with a screwdriver. Hold a
cloth around the screwdriver blade as a certain
amount of water may run out.
■
Insert a screwdriver and turn the pump rotor.
■
Screw in the venting screw.
■
Start FIGHTER 1220 and check whether the circu-
lation pump runs.
It is usually easier to start the circulation pump with
FIGHTER 1220 running, switch (8) set to 1. If helping
the circulation pump to start is performed with FIGHT-
ER 1220 running, be prepared for the screwdriver to
jerk when the pump starts.
Helping the circulation pump to start
Luftningsskruv
16
LEK
G
R
U
N
D
FO
S
T
ype
UPS
25 - 60
130
P/N:59526447
230V
-
HEJSAN
PC;0017NIB
D
K
50Hz
IP 44
TF 110
Class H
M
ax.
10bar
2.5uF
45
0.20
65
0.30
90
0.40
1m(A)
P,
(W)
Содержание FIGHTER 1220
Страница 2: ......
Страница 52: ...Wiring diagram 3 x 400 V N FIGHTER 1220 For the Installer 50 Sheet 3 4 Brine pump Relay board...
Страница 57: ...55 For the Installer FIGHTER 1220...
Страница 58: ...FIGHTER 1220 For the Installer 56...
Страница 59: ......