Sound pressure levels
F2015 is usually placed next to a house wall, which gives a
directed sound distribution that should be considered. Ac-
cordingly, you should always attempt to find a placement
on the side that faces the least sound sensitive neighbouring
area.
The sound pressure levels are further affected by walls, bricks,
differences in ground level, etc and should therefore only be
seen as guide values.
F2015 works with low fan speed or high fan speed depend-
ing on the outdoor temperature.
R
LEK
1 m
4 m
10 m
F2015-11
F2015-8
F2015-6
57/62
57/62
57
L
W
(A)
Sound power level
51/56
51/56
51
dB(A)
Sound pressure level at 1 m. Fan low/high
39/44
39/44
39
dB(A)
Sound pressure level at 4 m. Fan low/high
31/36
31/36
31
dB(A)
Sound pressure level at 10 m. Fan low/high