NOTE
Always cut the power before opening ERS 10.
LE
K
EP26
Water seal for condensation
water
The water seal must be installed so that it can be checked
by the user, without needing to open ERS 10.
The water seal may dry out during the hotter periods of
the year when no condensation is generated. Therefore,
before the cold periods of the year, the condensation
water drain must be checked for blockage due to dirt
and filled with water.
Pour approx. one litre of water into the water seal and
check that it runs through unobstructed.
The water seal must not dry out during those months of
the year that condensation is created because, due to
the negative pressure in the unit, air will be sucked into
the unit which will then prevent the condensation water
from running off. ERS 10 can produce several litres of
condensation water each day. If the condensation water
drain does not function, water may cause damage inside
the house.
Heat exchanger
The heat exchanger (EP26) must be inspected at regular
intervals. Every other year is recommended.
If it is dirty, it must be removed and vacuumed without
touching the fins.
Press gently from behind when removing the heat ex-
changer. Bear in mind that the fins are sensitive and
easily damaged.
NOTE
Do not damage the fins. If the fins are damaged
the output may be reduced.
17
Chapter 9 |
Service
NIBE™ ERS 10-500