Preparations
■
Check the miniature circuit-breaker (FA1) in the main
product. It may have tripped during transportation.
■
Check that the air filters are clean, they can become
dirty after installation.
Filling and venting
■
Check that there is water in the water seal, fill if neces-
sary.
Start-up and inspection
Setting the ventilation
Ventilation must be set according to applicable stand-
ards. The supply air flow is adjusted to ensure a negative
pressure. The settings are made in menus 5.1.5 and 5.1.6.
Even if ventilation is roughly set at installation it is import-
ant that a ventilation adjustment is ordered and permit-
ted.
Caution
An incorrectly set ventilation flow can damage
the house and may also increase energy con-
sumption.
NOTE
Order a ventilation adjustment to complete the
setting.
Ventilation capacity
Luftflöde (l/s)
Ventilationskapacitet
Tillgängligt
tryck
(Pa)
0
50
100
150
200
250
300
350
400
450
0
20
40
60
80
100
120
140
80%
100%
70%
60%
50%
40%
30%
Pressure
(Pa)
Airflow (l/s)
Output, fans
Luftflöde (l/s)
Effekt
Effekt
(W)
0
10
20
30
40
50
60
70
80
90
100
110
120
0
20
40
60
80
100
120
140
80%
100%
70%
60%
50%
40%
30%
Power
output
(W)
Airflow (l/s)
NIBE™ ERS 10-500
Chapter 6 |
Commissioning and adjusting
14
6 Commissioning and adjusting