Comfort setting cooling
General
The condition in order for cooling to be activated is that
"On" is selected in menu 9.3.3 Cooling system.
NOTE
The climate system must manage cooling operation.
Settings must be made by the installer when commis-
sioning the system.
If a room sensor is connected, it starts and stops cooling
together with the outdoor temperature. The lowest calcu-
lated supply temperature is set in menu 2.2.4 Min supply
cooling.
If a room sensor is connected, it starts and stops cooling
together with the outdoor temperature. The lowest calcu-
lated supply temperature is set in the menu.
Cooling operated from the outdoor sensor in
operating mode AutoK
If the cooling system is set to "On" in menu 9.3.3 and the
outdoor temperature is greater or equivalent to the set
start temperature for cooling in menu 8.2.4, cooling starts.
Cooling stops when the outdoor temperature drops below
the set value minus the set value in menu 8.2.5.
The current supply line temperature is determined from
the selected cooling curve in menu 2.2.2 and the offset
for cooling curve, menu 2.2.1. Limitations, which are not
in the diagram, are included in the control system's permit-
ted min temperature.
0
0
°C
20
°C
30
5
10
20
Beräknad
framlednings-
temp.
Utetemp.
40
15
Utetemperatur
Be räknad framledningstemperatur
20
30
40
20
10
0
k = 1
k = 2
k = 3
k=1
k=2
k=3
+ 5
- 5
FÖRSKJUTNING
KYLKURVA (0)
Outside temperature
Calculated flow
temperature
Cooling curve offset (0)
Controlling cooling mode using the room
sensor
If RG 10 is present, the condition for cooling is that the
room temperature has exceeded the set room temperature
(menu 6.3) by the set value in menu 8.2.5 and that the
outdoor temperature is equal to or exceeds the set outdoor
temperature value (menu 8.2.4).
When the room temperature has dropped below the set
room temperature in menu 6.3 by the set value in menu
8.2.5 or the outdoor temperature falls below the set value
in menu 8.2.4 by the set value in menu 8.2.5, cooling
switches off.
13
NIBE™ SPLIT ACVM 270
For Home Owners
Comfort setting cooling
Содержание ACVM 270
Страница 2: ...LEK LEK 1 2 LEK LEK 7 LEK 5 6 LEK 3 4 LEK LEK LEK LEK AMS 10 8 LEK LEK AMS 10 12 ...
Страница 66: ...Electrical circuit diagram ACVM 270 NIBE SPLIT ACVM 270 66 Miscellaneous Electrical circuit diagram ...
Страница 67: ...67 NIBE SPLIT ACVM 270 Miscellaneous Electrical circuit diagram ...
Страница 68: ...NIBE SPLIT ACVM 270 68 Miscellaneous Electrical circuit diagram ...
Страница 69: ...69 NIBE SPLIT ACVM 270 Miscellaneous Electrical circuit diagram ...
Страница 70: ...NIBE SPLIT ACVM 270 70 Miscellaneous Electrical circuit diagram ...
Страница 94: ......
Страница 95: ......