![NIBE-BIAWAR HK 200M Скачать руководство пользователя страница 11](http://html.mh-extra.com/html/nibe-biawar/hk-200m/hk-200m_installation-manual_1686585011.webp)
11
HK 200M
Indoor HK 200M module
•
It is recommended that the HK 200M module
should be installed in a room with a floor drain, at
best in a utility room or a boiler house.
•
The floor must be solid, concrete at best.
•
The HK 200M module must be set with its back
to the outer wall, at best in a room where noise is
not a problem. If possible, do not place the device
near a wall of a bedroom or another room where
noise might be a problem.
•
The device can be leveled using regulated legs.
•
Pipes must be led in such a way that they are not
adjacent to the bedroom or living room.
•
Remember to leave about 800 mm free space at
the front and 500 mm over the device to provide
for future maintenance.
1. Connect HK 200M module to the heating system,
cold, and hot water pipelines.
2. Use hydraulic connections to connect the outdoor
and indoor unit.
3. Connect the current meter, outdoor temperature
sensor, centralized current control, and cables
between HK 200S, AMS 10 and SMO 20/40.
4.
Connect power supply to module HK 200M.
5. Proceed according to start-up instructions in
chapter Start-up and regulation.
Recommended order of assembly
Chapter 4 |