Series 1060
5
This appliance was listed by LABTEST Certification Inc to the following USA and Canadian gas
appliance standards.
- ANSI Z21.88-2009/CSA 2.33-2009 Vented Gas Fireplace Heaters
- CAN/CGA-2.17-M91, Gas-Fired Appliances for Use at High Altitudes
-CSA P.4.1-09 testing method for measuring annual fireplace efficiency.
The listing label is attached to the appliance on the bottom right side of the appliance.
A copy is shown on page
Please contact Archgard Industries Ltd., if you have any questions regarding the certification of
this appliance.
APPLIANCE CERTIFICATION
INSTALLATION CODES
This appliance must be installed by a qualified gas appliance installer. The installation must
conform with the local codes or, in the absence of local codes, with the current National Fuel
Gas Code ANSI Z223.1/ NFPA 54 in the US, or Installation Code CAN/CGA-B149.1 in Canada.
Electrical connections and grounding must conform with local code, or current National
Electrical code ANSI/NFPA No. 70-1987 in the US, and in Canada the current Canadian
Electrical Code CSA C22.1.
A manufactured home (USA only) or mobile home OEM installation must conform with the
Manufactured Home Construction and Safety Standard, Title 24CFR, Part 3280, or, when such
a standard is not applicable, the Standard for manufactured Home Installations, ANSI/NCSBCS
A225.1 or Standard for Gas Equipped Recreational vehicles and Mobile Housing, CSA Z240.4
We recommend that our gas hearth products be installed and serviced by professionals
who are certified in the U.S. by the National Fireplace Institute
®
(NFI) as NFI Gas
Specialists.
SPECIFICATIONS
/.
Natural Gas (NG)
Propane (LP)
Manifold Pressure
3.5 in. W.C. (0.9 kPa)
10.0 in. W.C. (2.5 kPa)
Min. Supply Press
Max Supply Press
4.5 in. W.C. (1.2 kPa)
14.0 in. W.C. (3.5 kPa)
11.0 in. W.C. (2.8 kPa)
14.0 in. W.C. (3.5 kPa)
Orifice Size Center
Orifice Size Sides
See Table
See Table
Nominal Input
Rating
See Table
See Table
Electrical Rating
120 VAC, 60Hz less than 2 A. /
120 VAC, 60Hz less than 2 A. /
Gas Control
SIT
SIT
Altitude
0 - 4,500 ft. (0 - 1372 M)
0 - 4,500 ft. (0 - 1372 M)
Primary Air Opening
1/16” (3 mm) OPEN
1/4” (12 mm) OPEN
HIGH ALTITUDE INSTALLATION
When installing this appliance beyond 4500 ft. (1372 M) above sea level, the appliance must
be properly de-rated and installed according to local codes, in the absence of local codes, with
the current National Fuel Gas Code, ANSI Z223.1/ NFPA 54, in the US or Installation Code,
CAN/CGA-B149, in Canada.
Содержание 1060 Series
Страница 13: ...Series 1060 13 ELECTRICAL CONNECTIONS Figure 9 Figure 10 Figure 11 ...
Страница 15: ...Series 1060 15 ELECTRICAL CONNECTIONS Figure 15 ...
Страница 18: ...Series 1060 18 VALVE INCLUDED IN THE 1060 SERIES HONEYWELL SV950 SYSTEM Figure 16 Figure 18 Figure 17 ...
Страница 19: ...Series 1060 19 VALVE INCLUDED IN THE 1060 SERIES HONEYWELL SV950 SYSTEM Figure 19 ...
Страница 21: ...Series 1060 21 REMOTE CONTROL SETUP AND OPERATION SIT SYSTEM future option ...
Страница 22: ...Series 1060 22 REMOTE CONTROL SETUP AND OPERATION SIT SYSTEM cont Future Option Non Functional Option ...
Страница 23: ...Series 1060 23 REMOTE CONTROL SETUP AND OPERATION SIT SYSTEM cont ...
Страница 24: ...Series 1060 24 REMOTE CONTROL SETUP AND OPERATION SIT SYSTEM cont ...
Страница 25: ...Series 1060 25 REMOTE CONTROL SETUP AND OPERATION SIT SYSTEM cont ...
Страница 26: ...Series 1060 26 REMOTE CONTROL SETUP AND OPERATION SIT SYSTEM cont ...
Страница 27: ...Series 1060 27 REMOTE CONTROL SETUP AND OPERATION SIT SYSTEM cont ...
Страница 42: ...NIBART CUSTOM FIREPLACES 7116 Beatty Drive Mission B C V2V 6B4 Canada Website www Nibart Custom com ...
Страница 43: ...Series 1060 43 NOTES ...
Страница 44: ...Series 1060 44 NOTES ...