INITIAL OPERATION
1. Check that the appliance is properly vented and connected to the gas supply.
2. Check that all external parts, such as door and faceplate are properly attached and
fastened.
3. Do not operate this appliance with broken, cracked glass doors or without the door (s) in its
correct (and latched) position. Do not abuse the glass by either striking or slamming shut.
4. Check that there are no fingerprints left on glass panels, as high temperature can bake
these prints on permanently.
FINAL INSTALLATION CHECK
Each Nibart Custom Gas Fireplace is checked and tested at the factory prior to being pack-
aged and shipped to our dealers and finally installed in your home. Nibart recommends that
before leaving this unit with the customer, the installer must ensure that the appliance is firing
correctly and that the electrical system is in working order.
This will include:
1. Perform leak tests of supply line, gas control valve, supply line from gas control valve and
pilot assembly.
2. Clocking the appliance to ensure the correct firing rate
(see page 9 of this manual).
3. If required, adjusting the primary air to burner to ensure that the flame does not carbon or
soot.
4. Check for proper operation including correct drafting.
As a reminder, a TAG is attached to all of our gas fireplaces. This TAG is located at the gas
control valve. See Fig ?.
Any alteration to the product that causes carboning or sooting that results in any
damage or requires cleaning is not the responsibility of the manufacturer.
NIBART CUSTOM INDUSTRIES LTD.
*** INSTALLER ***
IMPORTANT NOTICE
ALL GAS AND ELECTRICAL CONNECTIONS
** MUST ** BE CHECKED AND TESTED AT
TIME OF INSTALLATION.
Fig ?.
Содержание 1060 Series
Страница 13: ...Series 1060 13 ELECTRICAL CONNECTIONS Figure 9 Figure 10 Figure 11 ...
Страница 15: ...Series 1060 15 ELECTRICAL CONNECTIONS Figure 15 ...
Страница 18: ...Series 1060 18 VALVE INCLUDED IN THE 1060 SERIES HONEYWELL SV950 SYSTEM Figure 16 Figure 18 Figure 17 ...
Страница 19: ...Series 1060 19 VALVE INCLUDED IN THE 1060 SERIES HONEYWELL SV950 SYSTEM Figure 19 ...
Страница 21: ...Series 1060 21 REMOTE CONTROL SETUP AND OPERATION SIT SYSTEM future option ...
Страница 22: ...Series 1060 22 REMOTE CONTROL SETUP AND OPERATION SIT SYSTEM cont Future Option Non Functional Option ...
Страница 23: ...Series 1060 23 REMOTE CONTROL SETUP AND OPERATION SIT SYSTEM cont ...
Страница 24: ...Series 1060 24 REMOTE CONTROL SETUP AND OPERATION SIT SYSTEM cont ...
Страница 25: ...Series 1060 25 REMOTE CONTROL SETUP AND OPERATION SIT SYSTEM cont ...
Страница 26: ...Series 1060 26 REMOTE CONTROL SETUP AND OPERATION SIT SYSTEM cont ...
Страница 27: ...Series 1060 27 REMOTE CONTROL SETUP AND OPERATION SIT SYSTEM cont ...
Страница 42: ...NIBART CUSTOM FIREPLACES 7116 Beatty Drive Mission B C V2V 6B4 Canada Website www Nibart Custom com ...
Страница 43: ...Series 1060 43 NOTES ...
Страница 44: ...Series 1060 44 NOTES ...