7.0 Diagnostic Messages
DiSPlaY
DESCRiPTiOn
Set F/R > Max Lt
For a given NB size whenever programmed flow rate is greater than the maximum
Reset Flow Rate
limit of flow rate, display will prompt the programmer and programming will jump to
Flow Rate Programming
Too High Flow
Whenever input flow rate is greater than the 110% of maximum limit this message
will appear on the display and the display will toggle with this message and the
instantaneous flow rate
XXX.X CuM/hr
This message will appear on the display whenever the HI Alarm Level is reached
XXXXXXX CuM H
XXX.X CuM/hr
This message will appear on the display whenever the LO Alarm Level is reached
XXXXXXX CuM L
000.0 CuM/hr
This message will appear on the display whenever the CS Level is reached
XXXXXXX CuM LC
H < L
Whenever set HI Alarm is less than LO Alarm while programming HI Alarm, display
Reset HI Alarm
will prompt the programmer with this message and programming will jump to HI
Alarm programming
H < L
Whenever set LO Alarm is greater than HI Alarm while programming LO Alarm,
Reset LO Alarm
display will prompt the programmer with this message and programming will jump
to LO Alarm programming
CS > L
Whenever set LO Alarm is less than CS Level while programming LO Alarm, display
Reset LO Alarm
will prompt the programmer with this message and programming will jump to Low
Alarm programming
CS > L
Whenever set LO Alarm is less than CS Level while programming Creep
Reset CS Level
Suppression, display will prompt the programmer with this message and
programming will jump to Creep Suppression programming
+XXX.X CuM/hr
Flow rate in forward direction and Forward Totalizer display
+XXXXXXXX CuM
-XXX.X CuM/hr
Flow rate in reverse direction and Reverse Totalizer display
-XXXXXXXX CuM
+XXX.X CuM/hr
This message will appear on display when empty pipe/half-filled pipe is detected
+XXXXXXXX CuM LE
Forward Mode
This message will appear on display when Uni-directional Forward Mode is selected
Selected
and flow in pipe line is finite and in reverse direction.
Reverse Mode
This message will appear on display when Uni-directional Reverse Mode is selected
Selected
and flow in pipe line is finite and in forward direction.
NOTE:
1. The display unit for flow rate will be according to set unit.
2. The Totalizer unit will be in CuM or Gal.
Содержание 6600 Series
Страница 12: ...9 Installation Operation Maintenance Manual M600 NIAGARA 1 6 Dimensional Drawing Integral or Remote ...
Страница 13: ...NIAGARA Installation Operation Maintenance Manual M600 Rev E 10 ...
Страница 14: ...11 Installation Operation Maintenance Manual M600 NIAGARA ...
Страница 15: ...NIAGARA Installation Operation Maintenance Manual M600 Rev E 12 ...
Страница 29: ...NIAGARA Installation Operation Maintenance Manual M600 Rev E 26 ...
Страница 30: ...27 Installation Operation Maintenance Manual M600 NIAGARA ...