NIAGARA
Installation, Operation & Maintenance Manual M600
Rev. E 8
Flow Ranges
NOTE: Minimum flow; divide full-scale flow by 10. Full-scale can be set any where between the full-scale flow
range given in the table below. Standard unit only.
Min. Min. Max. Dim. Dim. Dim.
line Meas. 20ma 20ma "a" "B" "C" Weight
Size Flow Setting Setting End to End Width Width (lb)
(in) (gPM) (gPM) (gPM) inches inches inches
0.50
0.14 1.40 25
8.268 6.457 7.047 22.04
1.00
0.40 4.00 80
8.268 6.457 7.047 30.81
1.50
1.00 10.00 195
8.268 6.457 7.047 35.27
2.00
1.50 15.00 310
8.268 6.457 7.047 39.68
3.00
4.00 40.00 790
11.204 8.78 9.213 59.52
4.00
6.00 60.00 1230
11.204 8.78 9.213 72.75
5.00 10.00 100.00 1980
13.386 13.661 14.09 99.2
6.00 14.00 140.00 2820
13.386 13.661 14.09 110.23
8.00 25.00 250.00 4975
13.386 13.661 14.09 121.25
10.00 39.00 390.00 7790
18.11 18.583 18.583 220.46
12.00 55.50 555.00 11095
19.291 20.784 20.784 286.6
14.00 76.00 760.00 15250 22.047 22.48 22.48
357.15
16.00 99.50 995.00 19900 24.016 25.472 25.472 429.9
18.00 126.00 1260.00 25200 25.984 27.362 27.362 487.22
20.00 155.50 1555.00 31100
25.984 28.465 28.465 694.46
24.00 220.00 2200.00 44900 31.102 32.992 32.992 826.73
20.00 155.50 1555.00 31100
25.984
28.465 28.465
694.46
24.00 220.00 2200.00 44900
31.102
32.992 32.992
826.73
Содержание 6600 Series
Страница 12: ...9 Installation Operation Maintenance Manual M600 NIAGARA 1 6 Dimensional Drawing Integral or Remote ...
Страница 13: ...NIAGARA Installation Operation Maintenance Manual M600 Rev E 10 ...
Страница 14: ...11 Installation Operation Maintenance Manual M600 NIAGARA ...
Страница 15: ...NIAGARA Installation Operation Maintenance Manual M600 Rev E 12 ...
Страница 29: ...NIAGARA Installation Operation Maintenance Manual M600 Rev E 26 ...
Страница 30: ...27 Installation Operation Maintenance Manual M600 NIAGARA ...