46
4.
BASIC OPERATION
MULTIFUNCTION GENERATOR
b) Items that can be changed in the phase setting
The following items can be changed with the phase setting.
■
The phase difference between the sync/sub-output’s reference phase sync output and
waveform output can be changed
The following example assumes a phase setting of +90°. At this time, the waveform output’s
zero phase position is 90° ahead of the rise of the reference phase sync output.
■
The oscillation start/stop phase for burst oscillation, gated single-shot sweep can be
changed
The following example is burst oscillation with the oscillation start/stop phase set to +30°.
At this time, the oscillation starts at +30° and stops at the same +30° position.
Burst oscillation:
)
p. 105, gated single-shot sweep:
)
p. 89.
Waveform output
Waveform output’s
zero phase position
Sync/sub-output
(reference phase sync output)
Phase setting: +90°
90°
Phase setting: +30°
Oscillation
start at +30°
Oscillation
stop at +30°