6.3 File format
FRA5097
6-11
Table 6-4 b) Measurement condition file format - Condition data (continued)
300(0x12C)
long[2]
(not yet used)
308(0x134)
double
Oscillator (OSC) frequency (Hz)
316(0x13c)
double
Oscillator (OSC) amplitude set value (Vpeak)
324(0x144)
double
Current oscillator (OSC) amplitude value (Vpeak)
332(0x14c)
double
Oscillator (OSC) DC bias set value (V)
340(0x154)
double
Current oscillator (OSC) bias value (V)
348(0x15c)
double
CH1 excessive (over) level detection level (Vrms)
356(0x164)
double
CH2 excessive (over) level detection level (Vrms)
364(0x16c)
double
CH1 WEIGHTING FACTOR 0.0 - 1.0E+06
372(0x174)
double
CH2 WEIGHTING FACTOR 0.0 - 1.0E+06
380(0x17c)
double
Maximum sweep frequency 0.1E
−
3 – 15E+6
388(0x184)
double
Minimum sweep frequency 0.1E
−
3 – 15E+6
396(0x18c)
double
Sweep resolution (Hz)
404(0x194) double
Integration
time
(sec)
412(0x19c)
double
Delay time (sec)
420(0x1a4)
double
Maximum integration time for automatic integration (sec)
428(0x1ac)
double
Reference level for amplitude compression (Vrms)
436(0x1b4)
double
Output limiting value for amplitude compression (Vpeak)
444(0x1bc) double
VARIATION
of
(dBR)
in
high-density slow sweep operation (dB)
452(0x1c4)
double
VARIATION of (R) in high-density slow sweep operation (Vrms)
460(0x1cc) double
VARIATION
of
(
θ
) in high-density slow sweep operation (deg)
468(0x1d4)
double
VARIATION of (a) in high-density slow sweep operation (Vrms)
476(0x1dc)
double
VARIATION of (b) in high-density slow sweep operation (Vrms)
484(0x1e4)
double
Display scale initial value : maximum frequency MAX(Hz)
492(0x1ec)
double
Display scale initial value : minimum frequency MIN(Hz)
500(0x1f4)
double
Display scale initial value : dBR MAX(dB)
508(0x1fc)
double
Display scale initial value : dBR MIN(dB)
516(0x204)
double
Display scale initial value : R MAX(Vrms)
524(0x20c)
double
Display scale initial value : R MIN(Vrms)
532(0x214)
double
Display scale initial value :
θ
MAX(deg)
540(0x21c)
double
Display scale initial value :
θ
MIN(deg)
548(0x224)
double
Display scale initial value : a MAX(Vrms)
556(0x22c)
double
Display scale initial value : a MIN(Vrms)
564(0x234)
double
Display scale initial value : b MAX(Vrms)
572(0x23c)
double
Display scale initial value : b MIN(Vrms)
580(0x244) double
DATA1 constant value in real number for the four rules of
arithmetic operation
588(0x24c) double
DATA1 constant value in imaginary number for the four rules of
arithmetic operation
Содержание FRA5097
Страница 1: ...NF Corporation FREQUENCY RESPONSE ANALYZER FRA5097 INSTRUCTION MANUAL ...
Страница 2: ......
Страница 3: ...DA00014283 002 FRA5097 Frequency Response Analyzer Instruction Manual ...
Страница 4: ......
Страница 35: ...2 2 Mounting and installation FRA5097 2 7 Fig 2 3 Removal of foot stands ...
Страница 40: ......
Страница 122: ......
Страница 132: ......
Страница 156: ......
Страница 168: ......
Страница 188: ......
Страница 190: ......
Страница 191: ......
Страница 192: ...http www nfcorp co jp NF Corporation 6 3 20 Tsunashima higashi Kohoku ku Yokohama 223 8508 JAPAN ...