3. Push the power button on the back of the HDR 1800. The power led on the front of the HDR 1800 lights 

up.

When the HDR 1800 first powers on, a splash screen with the unit’s IP address (DHCP or APIPA), device name, 

firmware version, and other information appear on all monitors. By default, the HDR 1800 is DHCP enabled. 

Before you can add the HDR 1800 to Nextiva VMS, you must assign a static IP address to the HDR 1800 in 

Nextiva VMS Control Center (see 

Configuring Network Settings

 on 

page 5

). 

Once the HDR 1800 powers up, you discover it in Nextiva VMS Control Center and configure its network and 

monitor output settings.

Discovering the HDR 1800 in Nextiva VMS

Nextiva VMS, version 6.1 Roll-up 4, includes the HDR 1800 Service Generator in Nextiva Control Center. The 

HDR 1800 Service Generator interfaces with HDR 1800s installed on the Nextiva network. Before you can use 

an HDR 1800 with Nextiva VMS, you must discover it using the HDR 1800 Service Generator. 

To discover the HDR 1800:

1. Launch Nextiva Control Center.
2. Select Global Settings > Adaptors.
3. Click HDR 1800 Service Generator on the left. The HDR 1800 Service Generator Browser pane is 

displayed on the right.

The HDR 1800 Service Generator Browser pane displays general information for discovered HDR 1800s, 

including the current configuration state of the unit: Partially Discovered, Fully Discovered, Configured, or 

Foreign State. Once an HDR 1800 is discovered, you configure its network and monitor output settings.

Configuring Network Settings

Before you can add an HDR 1800 to Nextiva VMS you must configure its network settings, such as specifying 

a static IP address for the HDR 1800, and providing the subnet mask and gateway.

To configure network settings for the HDR 1800:

1. In the HDR 1800 Service Generator Browser pane, 

select a Partially Discovered HDR 1800 that you 

want to configure. The configuration parameters 

for the HDR 1800 appear directly below the HDR 
1800 Service Generator Browser pane.

2. Select the Network tab.
3. Type a static IP address for the HDR 1800 in the IP 

Address box.

4. In the Subnet Mask box, type the subnet mask for 

the subnet the HDR 1800 is located on.

5. Type the IP address of the server that acts as the 

access point to another network in the Gateway IP 

Address box. The gateway IP address is optional.

6. Click Apply to save the configuration settings.

Содержание HDR 1800

Страница 1: ...The HDR 1800 includes the following components One Power Status LED Power button 19V DC 5 power receptacle One BNC connector for composite video NTSC PAL One Digital DVI D connector One VGA RGB connector One RS 232 DB9 serial port for CCTV keyboard connection One RS 422 DB9 serial port for CCTV keyboard connection Two RJ45 Ethernet 10 100 1000 Base T network connectors Four USB 2 0 ports One Line ...

Страница 2: ...ing area 2 Attach the four bumpons provided to each corner of the HDR 1800 using the provided screws 3 Place the unit on the flat surface 4 Ensure that you have access to both the front and rear of the unit and that the fan airflow is not blocked To install the HDR 1800 on a rack 1 Align the rack mount brackets with the holes on the side of the HDR 1800 2 Screw the rack mount brackets to the HDR 1...

Страница 3: ... on each side of the HDR 1800 Connecting the HDR 1800 This section provides the procedures for connecting the network and power cables video monitors and CCTV keyboards to the HDR 1800 Connecting the Network and Power Cables To connect the cable for network Plug an ethernet cable into the LAN1 network RJ 45 connector on the back of the HDR 1800 LAN2 is inactive To connect the cable for power 1 Con...

Страница 4: ...t uses an RJ45 connection but you need to configure the RJ45 to DB9 adaptor wires color coded to the appropriate pins on the DB9 To connect a CCTV keyboard Use the following wiring scheme to connect the CCTV keyboard s serial cable to the corresponding serial DB9 port on the back of the HDR 1800 Once the connection is done you must set the baud rate parity and other parameters for the serial port ...

Страница 5: ...ce Generator on the left The HDR 1800 Service Generator Browser pane is displayed on the right The HDR 1800 Service Generator Browser pane displays general information for discovered HDR 1800s including the current configuration state of the unit Partially Discovered Fully Discovered Configured or Foreign State Once an HDR 1800 is discovered you configure its network and monitor output settings Co...

Страница 6: ...s for the HDR 1800 For a Single monitor configuration a Deselect the Monitor 2 option default selection b Select the Tile Layout for the monitor c Select the Connector Type for the monitor DVI default VGA or Composite For a Dual monitor configuration a Select the Monitor 2 option The configuration settings for Monitor 2 are enabled In a Dual monitor configuration the Connector Type for the first m...

Отзывы: