Nexsan E48™/E48V™/E48VT™/E48P™ nominal input voltage is 110–240VAC, 47–63Hz. Cordset
specification in North America is IEC C13 to IEC C14 rated 250V/10A.
Typical power consumption for the E60 units is 1,164W (5.18A) for 600GB SAS drives and 806W (3.6A) for
3TB SATA drives. Peak current is up to 15A.
Typical power consumption for the E48 units is 1,059W (4.74A) for 600GB SAS drives and 684W (3.0A) for
3TB SATA drives. Peak current is up to 15A.
Cooling
Front panel: One 120mm 12V axial fan (life 40,000 hrs) per drive drawer, for a total of three.
Internal: Two double-gang 12V axial fans (life 40,000 hrs) per drive drawer, for a total of six.
PSUs: Four 12V axial fans (life 40,000 hrs) per PSU, for a total of eight.
Materials
Chassis, external: Galvanized sheet steel
Chassis, internal: Galvanized sheet steel divider plates and sub-assemblies
Fascia: ABS (blend) Thermoplastic UL 94 V.0
Environment
Ambient operating temperature: 5°C–35°C (41°F–95°F)
Minimum drawer operation temperature: 10°C (50°F)
Physical characteristics
12
Part Number: P0450139
Rev: A
www.nexsan.com
Nexsan E60™/Nexsan E48™
FRU Removal and Replacement Guide
1