HARDWARE SETUP PROCEDURE
8.3.4 GEO S12 vertical array rigidly mounted on a ceiling
Required items
•
1 x GEOS12-FBUMPER (/-5° bumper tilt when installed below a flat surface; if higher
bumper tilt is required, surface will have to be defined accordingly) ;
•
(N-1) x GEOS12-ANPL for a N x GEO S12 array (ANPL1 ranges from 0.2° to 3.15°, ANPL2
ranges from 5° to 10°, ANPL3 ranges from 16° to 30°)
•
Four 12mm diameter screws (
not provided
)
IMPORTANT
Ensure that the ceiling is strong enough to hold GEO S12 cluster weight and that the four
screws 12mm diameter and corresponding plugs required to fix the bumper under the
ceiling are properly dimensioned.
Procedure
•
(1) Set all GEO S12 side by side;
•
(2) Remove the four TORX screws holding connector plates on upper side of all GEO S12’s;
•
(3) Remove the connector plates from all Geo S12’s;
•
(4) Fill each screw hole with Locktite 243 or equivalent;
•
(5) Position bottom external plates, angle plates and top external plate from GEOS12-ANPL kit to
required inter-cabinet angle value between cabinets upper sides;
•
(6) Screw all shoulder screws from GEOS12-ANPL kits so that all plates and cabinets are
tightened together;
•
•
•
•
•
•
•
•
•
•
Содержание GEO S12 Series
Страница 48: ...Page 48 112 GEO S12 HARDWARE SETUP PROCEDURE ...
Страница 52: ...Page 52 112 GEO S12 HARDWARE SETUP PROCEDURE ...
Страница 54: ...Page 54 112 GEO S12 HARDWARE SETUP PROCEDURE DOWN CABINET UP CABINET ...
Страница 66: ...Page 66 112 GEO S12 HARDWARE SETUP PROCEDURE ...
Страница 105: ...TECHNICAL SPECIFICATIONS Page 105 112 8 mm 20 mm 13 4 8 GEO S12 Push Pins BLGEOS WEIGHT 0 032 KG 0 07 LBS ...
Страница 111: ...USER NOTES Page 111 112 15 USER NOTES ...