7.3.4
GEO S12 EN54 vertical array rigidly mounted on a ceiling
Required items
-
1 x GPI-BUMPER (/-5° bumper tilt when installed below a flat surface; if higher bumper tilt is required, surface will
have to be defined accordingly)
-
(N-1) x GPI-ANPL for a N x GEO S12 EN54 array (ANPL1 ranges from 0.2° to 3.15°, ANPL2 ranges from 5° to 10°, ANPL3
ranges from 16° to 30°)
-
4 x 12mm diameter screws (
not provided
)
IMPORTANT
Ensure that the ceiling is strong enough to hold 4 times GEO S12 EN54 cluster weight and that the four
screws 12mm diameter and corresponding plugs required to fix the bumper under the ceiling are properly
dimensioned.
Procedure
-
Set
all GEO S12 EN54 sideways according to cluster configuration
-
Remove
the four TORX screws holding connector plates on upper side of all GEO S12’s EN54
-
Remove the connector plates from all GEO
S12’s EN54
-
Position
bottom counter-plates, angle plates and top counter-plates from GPI-ANPL kit to required inter-cabinet angle value
between cabinets upper sides
-
Use
thread lock coated screws (or if not apply Loctite 243 or equivalent to shoulder screws) from GPI-ANPL kits
-
Screw shoulder screws so that all plates and cabinets are tightened together
-
Flip
the cluster upside down to access connector plates located on the down side
-
Repeat
all above steps
Содержание GEO S12 EN54 Series
Страница 34: ...TECHNICAL SPECIFICATIONS Page 34 53 System Manual GEOS12 EN54 9 1 2 Dimensions mm inches ...
Страница 36: ...TECHNICAL SPECIFICATIONS Page 36 53 System Manual GEOS12 EN54 9 2 2 Dimensions mm inches ...
Страница 38: ...TECHNICAL SPECIFICATIONS Page 38 53 System Manual GEOS12 EN54 9 3 2 Dimensions mm inches ...
Страница 40: ...TECHNICAL SPECIFICATIONS Page 40 53 System Manual GEOS12 EN54 9 4 2 Dimensions mm inches ...
Страница 52: ...USER NOTES System Manual GEOS12 EN54 Page 52 53 11 USER NOTES ...