TROUBLESHOOTING
This troubleshooting manual was created to help to investigate failures. If failures happen, see
the chart below to find the parts and service required to eliminate them, and contact your dealer
or distributor.
WARNING!
See the troubleshooting chart and contact your service team to eliminate any
failure you can’t handle.
Instructions for troubleshooting
Symptom
Reason
Troubleshooting
No impacts/
hits
Pressure and return hoses
reversed
Swap the pressure and return hoses
Nitrogen pressure level in gas
chamber
is too high
Adjust pressure level in the gas
chamber
In and Out ports are closed
Open in and out ports
Oil level is too low
Add some oil
Output of the tool is not in striking
position for piston
Push the tool deeper into
the
breaker body by pushing the
tool
with
your
equipment
Impact energy
is too low
Nitrogen gas leakage from the gas
chamber
Charge nitrogen into
the
gas
chamber
Uneven impact
rate
Filter blocked
Wash or replace filter
Low oil level in the tank
Add some oil
Oil is spoiled or contaminated
Change oil
Bad carrier’s performance
Contact carrier’s manufacture
service team
Piston or sleeve working area is
damaged
Contact your local dealer
Oil overheating
Cool the oil, check the performance
of the oil coolers
Increased oil consumption from the
base machine
Reduce the flow to required level
Содержание IMPULSE 100L
Страница 1: ...OPERATION MANUAL PARTS LIST HYDRAULIC BREAKER IMPULSE 100L S ...
Страница 2: ......
Страница 3: ...3 4 5 7 8 12 16 28 31 33 34 35 36 ...
Страница 27: ...27 WARNING Neglecting the following procedures will cause housing rust which will result in serious damage ...
Страница 38: ...38 NOTES ...
Страница 39: ......
Страница 40: ...NEXGEN Attachments Inc 1 866 921 0333 info nexgenattachments ca www nexgenattachments ca ...