6.8. Seals inspection
CAUTION!
Change all seals and gaskets every 1500 hours.
1
. If any leakage is detected, damaged seals and gaskets should be replaced.
Examples of
d
amaged seals
and gaskets are shown below:
2.
If any seal or gasket failure occurs, find and eliminate the cause. Be careful not to damage seals
with excessive strain.
6.9. Inspection of gap between tool and tool bush
ing
A
A
Too large of a gap between the tool and the sleeve due to wear can cause damage or breakage of
the tool, bushing and piston. It may also cause the formation of burrs on its surface and
consequently, leakage of hydraulic oil. Maximum wear limit between the tool and tool bushing is
shown in the chart below: