Connect the wires to the thermostat’s terminals according to the wiring
diagram on a cover.
1:
External 230V setback (if in use),
2:
Heater neutral,
3:
Main supply
neutral,
4:
Main supply line,
5:
Heater line,
6-7:
NTC floor probe.
STARTUP
After connecting the power to the thermostat for the first time the parame-
ters are initialized to default values.
Name of thermostat:
RANDOM number
Mode:
Floor
Floor temperature min:
5°C
Floor temperature max:
35°C
Floor temperature offset (calibration):
0°C
Air temperature min:
5°C
Air temperature max:
28°C
Air temperature offset (calibration):
0°C
Snow melting ON temperature min:
0°C
Snow melting ON temperature max:
10°C
Snow melting OFF temperature:
-25°C
Snow melting air humidity min:
30%
User program activated eco temp:
19°C
Externally activated eco temp:
19°C