11
Heating mode
Thermostat can measure and adjust
floor
temperature,
air
temperature or
it can melt snow and ice from stairs and driveways in
snow melting
mode.
Floor temperature min and max
Min and max values specify active range of knob.
Floor temperature offset (calibration)
If user’s temperature measurement has offset to knob setpoint this setting is
used to calibrate it.
Note, floor sensor inside the floor construction is much
warmer than real temperatures measured in room.
Air temperature min and max
In air mode it specifies active knob range.
Air temperature offset (calibration)
If user’s temperature measurement has offset to dial setpoint this setting is
used to calibrate it.
Note, Air temperature mode uses external sensor,
either cable or wireless.
Snow melting ON temperature min and max
Min and max setting specify the active knob range. When outdoor tempe-
rature is below this setting point the snow melting operation is active.