holding tool
contact
palm
equipment
bushing
1
For aluminium conductors : before installing the conductor contact, wire brush the conductor.
2
Insert, if necessary, the centre ring into the contact barrel according to the table in the contact installation
instruction.
3
Position the contact taking care that the contact hole aligns with the bushing hole.
4
Before tightening, distance
« Z »
must be between
225
and
230
mm.
5
Tighten the contact. Please refer to the installation instruction included with the contact.
6
After tightening, distance
« Z »
must be between
225
and
235
mm.
If necessary, adjust the position of the cable reducer until distance
« Z »
is within the tolerance range.
Using adhesive tape, secure the cable reducer.
Mechanical type contacts (Type TMBC-X)
B
cable reducer
Before tightening
After tightening
conductor
contact
Z = 225 - 230
Z = 225 - 235
adhesive
tape
IS91374-ENG - 489TB/G
-45/S - Revision 1
Page 6 of 9
!
FOR INFORM
ATION ONL
Y
Please alw
ay
s use the instruc
tions supplied in the k