background image

 

AeroVent

®

 Standard

 

ALWAYS wear appropriate personal protective equipment when operating the unit

!

 

 

 

AeroVent® Standard Manual / 4840.1117 

 

MAINTENANCE 

ITEM 

CHECK 

*REPLACE 

Lid Gasket 10004249 

 

Before each use 

As Necessary 

Safe2Filter 10004898 (2 pack) 

Monthly 

Every 60 days or 600 cans, more 

often for full cans 

Cobalt Points  10003377 

 

Before Each use 

As Necessary 

Bellow 10003791 

 

Every 180 days 

As Necessary 

Operating Clamp 10004208 

Before each use 

Lubricate regularly with light oil. 

(3-in-1, WD-40 etc.) 

 

 

 

   

    

 

 
 

 

PARTS LIST

 

Item   

 

 

 

Part   

Number    Description 

 

Number 

Item   

 

 

 

Part 

Number   Description  

 

Number

     Main Base Plate 

 

10004285 

 

     Support Foot (2 req) 

10004262 

 

     Operating Handle   

10004208 

 

     Swivel Foot  

 

10004294 

 

     Lid Handle   

 

10004195 

 

     Lid Grommet  

 

10002410 

 

 

     For plunger block   

 

 

     Plunger Block Kit    

10004248 

 

     

(

2”, 2.5” and 3”)

 

 

 

     Trough Liner w/can stop 

10003970 

9  

     Trough Liner Grommet 

10001874 

10 

     Lid Gasket   

 

10004249 

11 

     Trough Bellow 

 

10003791 

12 

     Trough Spring 

 

10004257 

13 

     Cobalt Point 

 

10003377 

14 

     Safe2Filter Filter Element  10004841 

15 

     Safe2Filter Filter replacement 

 

 

     Package of 2 

 

10004898 

16 

     Grounding Cable w/clamp  10003914 

17 

     Left Shroud  

 

10004286 

18 

     Right Shroud 

 

10004287 

19 

     Bellows Clamp (2 req) 

10003794 

20 

     Set Screw 10-

32 x 5/8”

 

10004167 

 

 

 

Swivel Foot  

#4 

Operating 
Handle #3 

Safe2Filter 

Filter #14 

Support Foot   

#2 

Lid 

gasket 

#10 

Right Shroud 

#18 

Left Shroud 

#17 

Trough liner w/ 

can stop #8 

Trough Liner  
Grommet #9 

Содержание Aerovent Standard

Страница 1: ...AeroVent Standard Manual 4840 1117 AeroVent Standard Product Manual ...

Страница 2: ...n place For example the AeroVent X as designed is intended to puncture mostly empty cans those exhausted through normal discharge However some users have chosen to puncture and drain cans that are close to full This quickly exhausts the effectiveness of the carbon filter requiring more frequent filter changes that may or may not be done Others have located the unit on a shop floor that is merely o...

Страница 3: ...cement Page 5 Safe2Vent Replacement Page 5 Warranty Page 6 Thank you and congratulations on your purchase of the AeroVent Standard aerosol can disposal system The AeroVent Standard has been designed to puncture and drain aerosol cans that have been used and are mostly empty It is not intended to continuously process full cans Please read over the instructions and make sure you understand operating...

Страница 4: ...o Smoking near the unit or waste collection containers Avoid static discharge Ensure that the unit grounding cable is attached to a suitable grounding source such as metal water pipe or grounding rod prior to operation Keep the collection container closed when not in use and kept in a cool well ventilated area away from ignition sources Only operate unit out of doors or in a well ventilated area W...

Страница 5: ...h each handle and mounting post hole Secure with one 5 16 18 locking nut and washer on each bolt and snug nuts at this time Pic 1 6 Place one of the Plunger Blocks into the hole on the closed lid assembly Lower the handle and adjust the swivel foot so that it is centered in the plunger block Completely tighten all nuts and bolts of the handle assembly to the mounting post at this time Pic 2 7 Inst...

Страница 6: ...nd open the lid to remove the can Note If aerosol cans are mostly full leave the handle in the locked position for 45 60 seconds to allow can to drain completely PRECAUTIONARY WARNING Do not use the AeroVent for draining expanding foam sealant aerosol products or spray adhesive products Always use the correct plunger block for the diameter of the can that you are draining The clamp must remain loc...

Страница 7: ...ase Plate 10004285 2 Support Foot 2 req 10004262 3 Operating Handle 10004208 4 Swivel Foot 10004294 5 Lid Handle 10004195 6 Lid Grommet 10002410 For plunger block 7 Plunger Block Kit 10004248 2 2 5 and 3 8 Trough Liner w can stop 10003970 9 Trough Liner Grommet 10001874 10 Lid Gasket 10004249 11 Trough Bellow 10003791 12 Trough Spring 10004257 13 Cobalt Point 10003377 14 Safe2Filter Filter Element...

Страница 8: ...r bushings to rotate assembly up Rotate the trough assembly upward and allow it to rest against the lid 4 Loosen the setscrew with a 3 32 hex key and then replace the point Tighten the setscrew against the new point Do not use locktight on this setscrew 5 Re assemble the unit in reverse order SAFE2FILTER REPLACEMENT 1 Remove the filter lid from the element by grabbing the edge and pulling upwards ...

Страница 9: ...06 To review the complete guidelines for warranty and returns please visit www newstripe com guidlinesforwarrantyandreturn Gasoline engines compressors pumps including airless and Transaxles are furnished with their respective manufacturer s warranties only Such components are not covered by any warranty of Newstripe Inc Where Newstripe elects to extend manufacturers warranties the warranty shall ...

Отзывы: