PART 1
INTRODUCTION
1.1 Safety and EMC Considerations
Refer to the CE Approval Section
EMC Considerations
•
Whenever EMC is an issue, always use shielded cables.
•
Never run signal and power wires in the same conduit.
•
Use twisted-pair wires for signal connections.
•
Install Ferrite Bead(s) on signal wires close to the instrument if EMC problems persist.
Failure to follow all instructions and warnings may result in injury!
1.2 Before You Begin
Inspecting Your Shipment:
Remove the packing slip and verify that you have received
everything listed. Inspect the container and equipment for signs of damage as soon as
you receive the shipment. Note any evidence of rough handling in transit. Immediately
report any damage to the shipping agent. The carrier will not honor damage claims
unless all shipping material is saved for inspection. After examining and removing the
contents, save the packing material and carton in the event reshipment is necessary.
Customer Service:
If you need assistance, please contact the Customer Service
Department nearest you.
Manuals, Software:
The latest Operation Manual as well as free configuration software
(iConnect), datalogging software (iLog), and Mail Notifier are available at
the website
listed on the cover page of this manual or on the CD-ROM enclosed with your
shipment
.
1.3 Description
View Tempe Humidity with a Web Browser.
The iServer let’s you monitor and
record Temperature, Relative Humidity and Dew Point over an Ethernet network or the
Internet with no special software except a Web browser. The iServer serves Active Web
Pages to display real time readings, display charts of temperature and humidity, or log
data in standard data formats for use in a spreadsheet or data acquisition program such
as Excel or Visual Basic.
Adjustable Charts.
The Java™ Applet chart scales are fully adjustable on the fly. For
example, the chart can display one minute, one hour, one day, one week, one month or
one year. Users can select channel 1, channel 2 or the difference of the two channels.
Temperature and humidity can be charted across the full span (-40 to 124ºC, and
0 to 100% RH) or within any narrow range (such as 20 to 30ºC).
Display and Chart Two Channels.
The iServer transmitters come complete with a
hu temperature probe for measurement of a single location. With the addition of a
second probe, the transmitter can measure and display hu temperature and
dewpoint in a second location up to twenty feet away. The transmitter can display and chart
absolute measurement in both locations, or a differential measurement between the two
locations. The second probe requires no change to the basic iServer transmitter hardware,
firmware or software. A second probe can be added at the time of purchase or in the
future. There is a choice of industrial probes in 2 inch and 5 inch (51mm and 137mm)
lengths, and a wand style for ambient indoor applications. A simple DB9 “Y” connector is
available for adding a second probe to the iTHX-W. No connector is required to add a
second probe to the DIN rail mounted iTHX-2
2