P.O. Box 1306
Newport Beach
California 92663
Phone: 714-751-0488
Fax: 714-957-1621
E-Mail: [email protected]
www.newmartelecom.com
Features:
• Protects mobile computers against system crash preventing lengthy reboot sequences and loss of data due to:
• Voltage dip during engine cranking.
• Voltage drop and decay due to loading high power accessories and aging batteries.
• Provides supplemental voltage in mili-seconds to mobile computers when low vehicle battery is sensed, ensuring no
interruption in power.
• Back-Up Battery maintains DC output voltage during dips and black-outs — preventing memory loss and system
crashes in mission critical mobile electronics. Internal back-up battery automatically switches online when the
vehicle’s battery voltage reaches 10.0 VDC. Vehicle battery auto-reconnects when vehicle voltage reaches 11.5 VDC
or higher.
• Internal Battery Charger
• Built-in, 3-Stage temperature compensated battery charger maintains internal battery at full charge, ready
to provide back up power for an extended period.
• Noise filter eliminates electronic noise and interference, providing clean power required by mobile electronics
for proper operation.
• Overvoltage transient protection prevents damage to sensitive circuitry due to voltage line spikes.
• When activated, load disconnect timer (TMR) eliminates dead vehicle batteries caused by power drain from radios and
mobile data terminals that must operate while the engine is off. Allows use of accessory loads per programmed
time limit (user adjustable) while preserving battery for emergency starting. Factory default is not active, see page 5.
• Built-in LVD (Low Voltage Disconnect) activates when the internal back-up battery reaches 9.6VDC; protecting the
internal battery from complete discharge.
• Power conserving circuitry places internal charger in sleep mode after approximately 30 minutes once charger switches
to float mode. Sleep mode duration adjustable (factory default is 6 hours), then charger comes back online to charge
and float battery for a minimum of 30 minutes before sleep mode is restarted.
Note:
Sleep mode is delayed if back-up
mode is detected before the 30 minutes has elapsed. Once again, when charger reaches float mode the 30 minute
delay starts.
• Alerts when system is operating on battery back-up.
• Power Status indictors provide visual system operational status/disconnect timer activation/troubleshooting.
• Conformal coated printed circuit board resists corrosion.
• Rugged, rust and corrosion resistant powder coated aluminum case provides protection for components.
• A
ll components selected for dependable performance in hostile environments.
• Two year limited warranty.
Motorola Work Station Features
• Provides output warning signals to mobile computers (such as Motorola® MW800 series work stations and video
recording system cameras).
• Initiates low voltage shut down sequence in mobile computers protecting data and hard drive.
2
D.C.Input Problems Here
VOLTAGE SPIKES
NOISE
LOSS OF POWER
VOLTAGE DIPS CAUSED
BY ENGNE STARTING
No Power Problems Here
RADIO
MOBILE COMPUTER TERMINAL