1. INTRODUCTION 

1-1 General Information 

 
Thank you for choosing NEWMAR as the power products supplier to your company.  NEWMAR’s Rackmount 
Pure Sine Wave Power Inverters are designed and built for full reliability at multiple locations and variety of 
applications.  These intelligent, dependable inverters provide economical AC Power for all your network needs.  
Operators spanning global continents have deployed the Rackmount Pure Sine Wave Power Inverters as the 
choice for high availability AC power support from a DC source.    
 
This manual contains information and technical details for all models in the Rackmount Pure Sine Wave Power 
Inverter family.  The general operation procedures are common, however in some instances, all or part of the 
information will not apply to the specific model purchased.  Refer to the specific model details page in Chapter 8: 
Technical Specifications. 

 

This user’s manual contains important technical instructions to be followed by qualified personnel 
responsible for the installation, start-up and maintenance of this unit.  We recommend that this manual 
be read attentively to insure safe and reliable operation of this equipment. 

 

Should you require any assistance, please call our Application 
Engineering department at: 

 
 

 

 

Tel: 800.854.3906 or 714.751.0488 

Fax: 714.957.1621 

Email: [email protected] 

 

2.  IMPORTANT SAFETY INSTRUCTIONS 

2-1  UL Safety Statement 

SAVE THESE INSTRUCTIONS - This manual contains important inverter instructions that should be followed during 
installation and maintenance of the Rackmount Pure Sine Wave inverter unit. 
To reduce the risk of electric shock, install the inverter in a temperature and humidity controlled indoor environment, 
free of conductive contaminants. Ambient temperature should not exceed 50

o

C (122

o

F). 

¾

  Depending on use, the AC output of the inverter may require a customer installed disconnect or fusing.  For 

telecom use, a GFCI has not been provided.  The inverter offers standard AC short circuit protection. 

¾

  The following precautions should be respected when working on the inverter: 

ƒ

  Remove watches, rings, or other metal objects. 

ƒ

  Use tools with insulated handles. 

ƒ

  Wear rubber gloves and boots. 

2-2  Other Safety Notes 

¾

  Upon receipt, examine the shipment box for damage. Notify the carrier immediately, before opening if damage is 

evident. 

¾

  Do not open or disassemble the inverter, warranty will be voided. 

Содержание 125-1000RM

Страница 1: ...INSTALLATION OPERATION MANUAL MODELS 24 1000RM 48 1000RM 48 1000IRM 48 2000RM 48 2000IRM 125 1000RM 125 2000RM Newmar 2911 W Garry Ave Santa Ana CA 92704 Tel 714 751 0488 Fax 714 957 1621 As of 8 11...

Страница 2: ...THE INPUT POWER 8 5 2 CONNECTING THE LOADS 8 5 3 FRONT PANEL OPERATION OF SEQUENCE SOFTWARE VERSION 0 0 OR 3 1 9 5 3A PROGRAMMING THE INVERTER SOFTWARE VERSION 0 2 OR 1 0 9 5 4 DATA BUTTON 9 5 4 DATA...

Страница 3: ...l be read attentively to insure safe and reliable operation of this equipment Should you require any assistance please call our Application Engineering department at Tel 800 854 3906 or 714 751 0488 F...

Страница 4: ...rounding of rack mounted equipment should be maintained Inverter DC power connection must be from a VDC source within the technical specifications of the unit under installation 2 3 Symbols PROTECTIVE...

Страница 5: ...first option Off Line mode AC output power will be supplied through the AC bypass mode in its normal operation Upon AC input failure output power will be diverted through the DC to AC inverter mode O...

Страница 6: ...frequency etc and system status can be shown sequentially on the LCD display by pressing these two buttons For more information Refer to Section 5 Operation Ventilator The ventilator on the front pane...

Страница 7: ...ce panel AC I P neutral to earth connection provided externally Usually service panel Operation On Line Mode DC input supplied from battery DC power system Inverter originated AC therefore neutral to...

Страница 8: ...plug to terminal conversion is used to secure bare wire load circuit wiring to the output sockets of the inverter The adapter includes strain relief for the wires being connected to the terminals Docu...

Страница 9: ...than 1 second the CPU will not start up correctly The inverter is in a normal operation condition when either of the following messages appear on the LCD screen 5 3a Programming the Inverter The INVER...

Страница 10: ...verter voltage INVERTER VOLT V C Output frequency Shows present output frequency OUTPUT FREQ Hz D Bypass AC voltage Shows present input bypass AC voltage BYPASS AC VOLT V E Bypass AC frequency Shows p...

Страница 11: ...TUS button to select the following information which is displayed on the LCD screen A Output status a When the input bypass voltage is normal and INVERTER output voltage is from DC to AC inverter LCD...

Страница 12: ...CD shows AMBIENT OVER TEMPERATURE d When the INVERTER output is in short circuit detection mode LCD shows INVERTER SHORT CIRCUIT e When the INVERTER output is overloaded beyond rated capacity LCD show...

Страница 13: ...the input bypass is over normal frequency range LCD shows BYPASS AC OUT OF FREQ f When the output is overloaded LCD shows BYPASS AC OVER LOAD D Input DC status a When the input DC voltage is normal IN...

Страница 14: ...VAILABLE EEPROM checksum error 6 MAINTENANCE AND TROUBLESHOOTING 6 1 Maintenance Make sure that the inverter vents are not blocked Use a vacuum cleaner to clear any dust from the fan area When cleanin...

Страница 15: ...95Vac 135Vac 100Vac 140Vac AC Bypass Frequency Range F 50Hz 45 5Hz 54 5Hz AC Bypass Frequency Range F 60Hz 55 5Hz 64 5Hz AC Bypass Recovery From Over Voltage 115Vac 125Vac 130Vac 135Vac AC Bypass Rec...

Страница 16: ...requirement to manage multiple network elements from a central location SNMP remote access as easy as installing the plug n play card configuring your network IP address and attaching the network inte...

Страница 17: ...1KVA 800W Voltage 100 110 115 120 VAC Voltage Regulation 2 Frequency 50 60Hz 0 2Hz Wave Form Pure Sine Wave THD linear load 3 120 V 100 THD SPS load 5 120 V 100 Crest Factor 3 1 Receptacles 4 NEMA 5 2...

Страница 18: ...20 V 100 THD SPS load 5 120 V 100 Crest Factor 3 1 Receptacles 4 NEMA 5 15 R outlets Utility Power Bypass Voltage Nominal 120 VAC Frequency 50 60 5 Hz Protection AC Circuit Breaker Protection Short Fo...

Страница 19: ...120 V 100 THD SPS load 5 120 V 100 Crest Factor 3 1 Receptacles 4 NEMA 5 20 R outlets Utility Power Bypass Voltage Nominal 120 VAC Frequency 50 60 5 Hz Protection AC Circuit Breaker Protection Short F...

Страница 20: ...120 V 100 THD SPS load 3 120 V 100 Crest Factor 3 1 Receptacles 4 NEMA 5 15 R outlets Utility Power Bypass Voltage Nominal 120 VAC Frequency 50 60 5 Hz Protection AC Circuit Breaker Protection Short...

Страница 21: ...5 120 V 100 THD SPS load 3 120 V 100 Crest Factor 3 1 Receptacles 4 NEMA 5 20 R outlets Utility Power Bypass Voltage Nominal 120 VAC Frequency 50 60 5 Hz Protection AC Circuit Breaker Protection Short...

Страница 22: ...V 100 THD SPS load 5 120 V 100 Crest Factor 3 1 Receptacles 4 IEC 320 outlets C13 Utility Power Bypass Voltage Nominal 230 VAC Frequency 50 60 5 Hz Protection AC Circuit Breaker Protection Short For...

Страница 23: ...0 V 100 THD SPS load 5 120 V 100 Crest Factor 3 1 Receptacles 4 IEC 320 outlets C13 Utility Power Bypass Voltage Nominal 230 VAC Frequency 50 60 5 Hz Protection AC Circuit Breaker Protection Short For...

Страница 24: ...Page 24 Drawing No MPXXXNX02ABX...

Страница 25: ...iguring your network IP address and attaching the network interface cable Locking Hardwire Adapter Reliable locking NEMA 5 15 plug to secure load circuits to the output sockets of the inverter Heavy d...

Отзывы: