Northern Ireland Association of Chimney Sweeps. Both associations have a register of
suitably qualified chimney sweeping and inspection services that issue certificates after
inspection.
If the stove is to be left unused for a prolonged period, then it should be given a thorough clean
to remove ash and unburned fuel residues. To enable a good flow of air through the appliance
to reduce condensation and subsequent damage, leave the air controls fully open.
It is important that the flue connection, any appliance baffles or throat plates and the chimney
are swept, cleaned, and inspected by an approved and registered chimney sweep prior to
lighting up after prolonged shutdown periods.
The installer may have fitted a permanent air supply vent into the room in which the stove is
installed to provide combustion and / or ventilation air. This air vent should not under any
circumstances be shut off or sealed.
An approved Carbon Monoxide detector alarm conforming to the latest edition of BS EN
50291
must be
installed into the room the stove is installed. Installation and positioning must
be in accordance with current National laws, Building Regulations including Approved
Document J (England & Wales) and alarm manufacturers instruction.
Actions to take if the alarm sounds in a CO emergency
If
you suspect fumes are escaping from your combustion appliance into your home, or your
carbon monoxide alarm goes off.
Turn the appliance off, by closing the air controls.
Open doors and windows to ventilate the building.
Leave the building immediately and do not return until your appliance has extinguished and
the air in the room is clear.
If you feel unwell go to your doctor, or call one of the following:
NHS England on 111
NHS Direct on 0845 46 47 (in Wales)
NHS 24 on 111 (in Scotland)
If it is urgent phone 999 for an ambulance. Tell them you feel your symptoms may be related
to carbon monoxide poisoning.
Before you reuse the appliance, have it serviced by a HETAS Registered Installer (England
& Wales) or equivalent approved installer for other nations and the chimney swept by
an approved chimney sweep.
Do not use the appliance until you are told it is safe to do so.
Provisions of an alarm must not be considered a substitute for either installing the
appliance correctly or ensuring regular servicing and maintenance of the stove and
chimney system.
Содержание Rydal 5 SE
Страница 8: ...8 Figure 1 2 Top baffle positioning Figure 1 3 Left hand stove vermiculite fire cheek positioning...
Страница 10: ...10 Fig 1 6 Showing top steel baffle in position lower baffle positioning Fig 1 7 Stove main grate positioning...
Страница 49: ...49 3 7 Exploded view with part identification for Rydal 5 SE...
Страница 52: ...52 3 8 Declaration of Performance...
Страница 53: ...53 3 9 Energy Label...