or leaks at the cleaning door or flue collar.
Unsealed, unused fireplaces are connected to the chimney.
The flue is blocked, e.g., by soot, due to inadequate cleaning, loose debris or even a birds nest.
The room to which the stove is installed is too tightly sealed. See section 2.8 Ventilation
Fresh air supply).
A good draft is achieved when:
The temperature difference between the flue way or chimney and outside atmosphere is high.
(Higher temperature in flue way or chimney and cooler temperature to external atmosphere).
This also applies during firing, when the need is greatest.
The weather is clear and there is a good wind.
The chimney is of the correct height.
The room that the stove is installed is adequately ventilated.
2.92 Carbon Monoxide Alarm
Refer to current National laws, Building Regulations, & any Rules in Force, including BS
8303 and BS EN 15287-1:2007. Also refer to Approved Document J (England & Wales)
An approved Carbon Monoxide alarm conforming to the latest edition of BS EN 50291
must be
installed into the room into which the stove is installed. Installation and positioning
must be
in
accordance with current National laws, Building Regulations and any Rules in Force including
Approved Document J (England & Wales). Also refer to the alarm manufacturer's instructions.
2.95 Handle. Figures 3.5 - 3.5A - 3.5B
This stove is supplied with three types of handles for customer preference. One is a Bakelite
handle; the second is a removable stainless-steel handle and the third is provision to fix the
stainless-steel handle into position.
Handle assembly
This stove is assembled with one type of handle when manufactured. If your preference is to use
one of the other two handles supplied, then please refer to the handle assembly pictures and
instructions on how to change. A stove mitten is supplied with this stove for your use when
operating the stove, if the mitten supplied is of the incorrect size for the user then it is
recommended that the user sources a CE approved stove mitten or glove to the correct size before
lighting and operating this stove. Refer to the end user for the handle configuration required before
installation.
Important.
Only change the handles when the stove is cold and not being used.
Содержание Rydal 5 SE
Страница 8: ...8 Figure 1 2 Top baffle positioning Figure 1 3 Left hand stove vermiculite fire cheek positioning...
Страница 10: ...10 Fig 1 6 Showing top steel baffle in position lower baffle positioning Fig 1 7 Stove main grate positioning...
Страница 49: ...49 3 7 Exploded view with part identification for Rydal 5 SE...
Страница 52: ...52 3 8 Declaration of Performance...
Страница 53: ...53 3 9 Energy Label...