Newman Easedale 5 SE Скачать руководство пользователя страница 16

 

16

particularly in situations where there is a safety risk to children or the infirm. When using this 
stove in situations where children, aged and / or infirm persons are present a fireguard 
manufactured in accordance with BS 8423:2010 + A1: 2016 must be used and such persons must 
be supervised at all times. 
It is also recommended that all other people should use a fireguard in accordance with BS 
8423:2010 + A1: 2016 at all times when the stove is alight or hot.   

2.4 The chimney. 

 

Refer  to  current  National  laws,  Building  Regulations,  &  any  Rules  in  Force,  including 
British  standard  BS  EN  15287-1:2007  and  BS  8303.  Also  refer  to  Approved  Document  J 
(England & Wales) 
 

The construction of the masonry chimneys, flue block chimneys and connecting flue pipe system 
must meet the requirements of the current National laws, Building Regulations, and any Rules in 
Force. 
This stove must 

never 

be connected to any shared chimney. 

An  efficient  modern  stove  places  heavy  demands  on  the  chimney,  and  you  should  have  the 
chimney regularly swept and inspected at least twice a year for smokeless fuel use and quarterly 
for wood fuel use by an approved chimney sweep. 
The  flue  or  chimney  system  must  be  in  good  condition.  It  must  be  inspected  and  swept  by  a 
competent  registered  person  and  passed  for  use  with  the  appliance  before  installation.  The 
National  Association  of  Chimney  sweeps  (NACS)  and  for  Northern  Ireland  (NIACS)  Northern 
Ireland  Association  of  Chimney  Sweeps  offer  a  register  of  approved  chimney  sweeping  and 
inspection services who will issue certificates after inspection and sweeping. 
Where the chimney is believed to have previously served an open fire installation it is possible that 
the higher flue gas temperatures from a closed appliance may loosen deposits that were previously 
firmly adhered, with the consequent risk of flue blockage. It is therefore recommended that the 
chimney be swept a second time within a month of regular use after installation. 
If it is necessary to fit a register plate it must conform to the current National laws, Building 
Regulations, and any Rules in Force.   
The minimum height of the flue or chimney must be 4.5m from the hearth to the top of the flue, 
with no horizontal sections and a maximum of 4 bends. Bends must have angles of less than 45 
degrees from the vertical. There should be at least 600mm of vertical flue pipe above the appliance 
before any bends are introduced. Ensure the connecting flue pipe is kept a suitable distance from 
any combustible material and does not form part of the supporting structure of the building.   
The installer must ensure the flue pipe diameter is not less than the diameter of the outlet of the 
appliance and does not narrow to less than the size of the outlet at any point in the system. 
Make provision to remove the appliance without the need to dismantle the chimney.   
Any existing flue must be confirmed as suitable for the new intended use as defined in the current 
Building Regulations.   
The flue or chimney systems must be inspected and swept to confirm the system is structurally 
sound and free from obstructions by an approved and competent chimney sweep.   
The flue exit from the building must comply with National laws, current local building control 
rules, Building regulations and any Rules in Force.   
Chimney heights and / or separations may need to be increased in particular cases where wind 
exposure, surrounding tall buildings, high trees or high ground could have adverse effects on flue 
draught 

Содержание Easedale 5 SE

Страница 1: ...Easedale 5 SE Multi fuel burning stove Installation user instructions To be left with customer Edition 1 Reference NS 21 Date 5TH March 2020...

Страница 2: ...l twin walled insulated flue system 2 8 Ventilation Fresh air supply 2 9 Chimney Draft 2 92 Carbon Monoxide Alarm 2 95 The handle 2 96 Commissioning and handover 3 0 User Manual 3 1 Maximum fuel loads...

Страница 3: ...l requirements of Health Safety at Work Act are observed implemented as stated on the date of installation Due to the weight of this stove adequate facilities must be available for loading unloading i...

Страница 4: ...rthern Ireland Therefore it is a requirement that fuels burnt or obtained for use in smoke control areas have been authorised in Regulations and that appliances used to burn solid fuel in those areas...

Страница 5: ...weight 65kgs Dimensions distances etc Figure 2 2A Technical data according to EN 13240 A2 2004 Nominal heat output Wood 5 0kw Approved smokeless fuel 5 0kw Flue gas mass flow Wood 3 9 g sec Approved...

Страница 6: ...any Rules in Force including current issues of British Standard BS 8303 code of practice for installation of domestic heating and cooking appliances approved solid mineral fuel and British Standards...

Страница 7: ...ocated Check the baffles and all other parts are located into correct positions including side bricks bottom bricks grate assembly banking bar and ash pan Before lighting the stove for the first time...

Страница 8: ...8 Figure 1 2 Bottom brick positioning Fig 1 3 Grate positioning...

Страница 9: ...9 Fig 1 4 Lower baffle positioning Fig 1 5 Side view of stove showing lower baffle position...

Страница 10: ...10 Fig 1 6 Left right hand bricks Note the right hand brick has a cut out to clear handle assembly Fig 1 7 Banking bar positioning...

Страница 11: ...11 Fig 1 8 Ash pan positioning...

Страница 12: ...of the stove This shows important information including a Model b Standard number c Production date d Dimensions e Serial number f Weight g Recommended fuel h Co Emissions j Efficiency k Nominal heat...

Страница 13: ...erimposed hearth The dimension of the superimposed hearth in front of the stove must be a minimum of 300mm all other dimensions of the superimposed hearth and constructional hearth must be in accordan...

Страница 14: ...ll surrounding non combustible brick walls have a minimum thickness of 200mm the clearance between the rear sides of stove can be reduced to 50mm refer to current National laws Building Regulations an...

Страница 15: ...uding BS 8303 and BS EN 15287 1 2007 Also refer to Approved Document J England Wales Clearances to furniture and soft furnishings Serious consideration should be given to positioning of furniture or s...

Страница 16: ...fire installation it is possible that the higher flue gas temperatures from a closed appliance may loosen deposits that were previously firmly adhered with the consequent risk of flue blockage It is...

Страница 17: ...the placement of chimneys and flues in connection with thatched roofs The chimney or flue system must be equipped with access doors for inspection and cleaning The size of the cleaning door in the ch...

Страница 18: ...uding BS 8303 and BS EN 15287 1 This must be confirmed with HETAS or Local Authority Building Control and all current National laws Building regulations and any Rules in Force Fig 3 The left picture s...

Страница 19: ...uding BS 8303 and BS EN 15287 1 This must be confirmed with HETAS or Local Authority Building Control and all current National laws Building regulations and any Rules in Force 2 7 Connecting to a stai...

Страница 20: ...Regulation any other Rules in Force Installation of purpose provided air vents must be installed to comply with current National laws Building Regulation any other Rules in Force Extractor fans or any...

Страница 21: ...ooler temperature outside Other factors that can influence the level of draft include the length of the flue insulation of the chimney adverse weather conditions or tall buildings or trees nearby the...

Страница 22: ...bled with the stainless steel handle assembly when manufactured A stove mitten is supplied with this stove for your use when operating the stove if the mitten supplied is of the incorrect size for the...

Страница 23: ...nal doors and windows fully closed Check the effect of any ceiling fans that may be installed on their maximum setting If the smoke spillage test fails re check the flue system and room ventilation Pr...

Страница 24: ...he room the appliance has been installed to use a suitable fireguard Explain to the user that a suitable fireguard must be used when the appliance is left unattended Record the appliance serial number...

Страница 25: ...and using the long ash pan key It is recommended to always use approved stove tongs for loading and refueling the stove with wood and smokeless fuels to avoid any part of your arms and hands entering...

Страница 26: ...Monoxide detector alarm conforming to the latest edition of BS EN 50291 must be installed into the room the stove is installed Installation and positioning must be in accordance with current National...

Страница 27: ...re adequate protection must be provided particularly in situations where there is a safety risk to children or the infirm When using this stove in situations where children aged and or infirm persons...

Страница 28: ...d re fueling may occur However persistent fume emission is potentially dangerous and must not be tolerated If fume emission does persist then the following immediate action should be taken Open doors...

Страница 29: ...ie flat over the layer of embers with air at both ends The maximum length of wood to be no more than 25cm Maximum fuel load wood The maximum fuel load to be one or two small to medium sized logs total...

Страница 30: ...erator or use any liquid fuels This is very dangerous and may damage the product and pollute the atmosphere Non approved smokeless fuels such as household coal All other fuels 3 2 Use Important The Ea...

Страница 31: ...lated by using the secondary air control The secondary air air wash system which is supplied to the combustion chamber over the internal glass is controlled using the upper air control lever move to t...

Страница 32: ...ficient burning material in the fire bed to light a new fuel charge excessive smoke emission can occur Re fuelling must be carried out onto a sufficient quantity of glowing embers and ash so that the...

Страница 33: ...gnition refueling and removal of residue material It is recommended providing the ash pan is not full of residue material that the ash pan is emptied when the fire is not in use and the stove and all...

Страница 34: ...stove will be operating at the nominal heat output of about 5kw Re fuelling See figure 4 1 When the fuel being burnt is low and requires to be refueled open the primary air control 2 Open the glass s...

Страница 35: ...excessive smoke The appliance must not be operated with the appliance door left open except as directed in the instructions Stove shut down For both wood and solid fuel If there is still fuel burning...

Страница 36: ...closed except during ignition refueling and removal of residue material It is recommended providing the ash pan is not full of residue material that the ash pan is emptied when the fire is not in use...

Страница 37: ...nd any hazard pending final disposal If the ashes are disposed of by burial in soil or otherwise locally dispersed they should be retained in the closed container until all cinders have completely coo...

Страница 38: ...nded that these parts should be changed at least annually of before if required Whist all the non bolted parts are removed from the inside of the stove clean all remaining internal stove parts check a...

Страница 39: ...ss panel to door DO NOT over tighten the screws as this can damage the glass Replacing the glass rope seal Remove the stove door by removing the 4 screws retaining the hinges to the door and place fac...

Страница 40: ...rape old glue from the locating grooves Clean the locating groove with a clean dry cloth to remove all old dust and debris Squeeze a generous bead of fresh stove rope seal glue into the rope locating...

Страница 41: ...uitably qualified stove installer regularly to ensure continued safe and efficient operation of this appliance Cleaning and maintenance only to be carried out when the stove is not in use and cold 3 3...

Страница 42: ...is essential to check the top of the baffles for build up of soot and ash regularly weather the stove has been used or not used From time to time remove the baffles if necessary to ensure that the flu...

Страница 43: ...stove is re painted Refer to the approved heat resistant spray paint manufacturer s instructions This process is recommended to be carried out by an approved and competent stove installer such as Het...

Страница 44: ...ning time is short Wet wood Use dry seasoned hardwood Over 20 moisture content Less than 20 moisture content Heat output too high Over firing Flue draught high Consult your stove installer Air control...

Страница 45: ...correct Consult your stove installer Evacuate all people from the room into a safe area If safely possible open all outside doors and widows to the effected room to ventilate Vacate the Smoke is emitt...

Страница 46: ...weather conditions can contribute to flue down draughts Consult your stove installer Intermittent smoke enters the room Poor flue draught usually when the stove door is opened on caused by an over si...

Страница 47: ...ue joints expelling tar Warning Do not exceed the maximum fuel load stated Refer to user instructions Poor quality wood being used Use dry seasoned hardwood Less than 20 moisture content Stove operate...

Страница 48: ...in the flue and stove Consult an approved chimney sweep if you are experiencing tar and creosote problems before continued use of the stove Consult a qualified heating engineer if you experience cont...

Страница 49: ...49 3 7 Expolded view with part identification for Easedale 5 SE...

Страница 50: ...50 3 8 Declaration Of Performance...

Страница 51: ...51 3 9 Energy label The Energy label shown uses wood as the preferred fuel...

Страница 52: ...ion EU 2015 1186 Energy Labelling of Local Space Heaters Manufacturer Name Newman Fireplaces Model Name Easedale 5 SE Energy Efficiency Class A Nominal Heat Output to Room kW 5 0 Nominal Heat Output t...

Страница 53: ...53 Address Units 6 7 Rawreth Barns Dollyman s Farm Doublegate Lane Rawreth Wickford Essex SS11 8UD Tel 01268 763586 Fax 01268 762366...

Отзывы: