![Newman Easedale 5 SE Скачать руководство пользователя страница 15](http://html1.mh-extra.com/html/newman/easedale-5-se/easedale-5-se_installation-and-users-instructions_1679779015.webp)
15
and other
non
-combustible fireplace types is being installed in conjunction with this stove that the
fireplace supplier is contacted to see what recommended clearances are required between the stove
and the fireplace, although most natural stone and marble is non-combustible there is a possibility
of the stone or marble being damaged such as cracking if the stone or marble material is heated
excessively.
Ceiling protection.
Refer to current National laws, Building Regulations, & any Rules in Force, including BS
8303 and BS EN 15287-1:2007. Also refer to Approved Document J (England & Wales)
Clearances to furniture and soft furnishings
Serious consideration should be given to positioning of furniture or soft furnishings that could be
adversely affected by heat. Newman Fireplaces Ltd recommend that any furniture or soft
furnishings should be a minimum distance of 2000 mm away from the stove.
NEVER
use or store
aerosol sprays or any other combustible products in the vicinity of the stove when it is in operation
or whenever the stove is hot. The stove will remain hot for some time even after the fire is
extinguished.
When lit, a wood-burning stove gets hot and therefore adequate protection must be provided,
Содержание Easedale 5 SE
Страница 8: ...8 Figure 1 2 Bottom brick positioning Fig 1 3 Grate positioning...
Страница 9: ...9 Fig 1 4 Lower baffle positioning Fig 1 5 Side view of stove showing lower baffle position...
Страница 11: ...11 Fig 1 8 Ash pan positioning...
Страница 49: ...49 3 7 Expolded view with part identification for Easedale 5 SE...
Страница 50: ...50 3 8 Declaration Of Performance...
Страница 51: ...51 3 9 Energy label The Energy label shown uses wood as the preferred fuel...