27
Select
GAtE
from main menu
Minimal gating distance of 0 meters (display: 000 m) will
be initially set, further pressing M button will increase
gating distance by 100 m up to 3,900 m. When the
desired distance is reached – select it by pressing
Action
button.
OVER 100M
– indicates that gating is active
To deactivate gating choose gating value zero.
NOTE:
The gating distance can only be increased. To
exit the gating selection cycle without setting any gating
distance click through full gating range with
M
button or
hold
M
button for 2 seconds.
Gating feature helps measuring remote targets in
unfavourable atmospheric and environmental conditions
by eliminating reflections from snowflakes, raindrops,
industrial wires, tree branches, etc. At the same time, if
gating distance is set incorrectly, you can remove the
desirable object from measurement range.
5.10
Data Recall mode
In
Data Recall
mode results of the last 10 measurements
can be displayed.
Measurement results are saved in on-board memory in
sets depending on the parameters set for measuring, for
instance, if only distance is measured - the set will consist