background image

 

                                               Part No. 803171 Issued 3-28-13 Rev 011515 

 

 

 

 

 

 

 

 

 

 

 

 
 
 
 
 

 

 

 

 

 

 

 
 
 
 
 

 
 
 
 
 
 
 
 
 
 
 
 
 

 
 

 

 

 
 
 

 
 

Rotate Dial Counter Clockwise For 

Stronger Mixture Or Clockwise 

For Leaner Mixture. Make small 

adjustments(approximately 1 ½ 

points or 1/8 turn at a time)

 

After Adjustments Are Made 

Replace Access Panel  

&  Tighten Screw 

 

 

Replace Product And Syrup Lines. 
 

 
 
 

Replace Top Cover. 

Содержание 872B

Страница 1: ...h the water A built in water pressure regulator ensures the proper amount of syrup is being mixed with the proper amount of water This built in pressure regulator is factory adjusted for a static pres...

Страница 2: ...fitting on rear of dispenser Fitting may vary 4 Turn on the water source to the dispenser 5 Turn the yellow handle to the ON position to allow water to flow through the urn Product Loading 1 Open the...

Страница 3: ...unit or when changing product Flush should be performed at least once a week Note Cleaning requires the use of a cleaning flush adapter An adapter may be purchased from Newco Enterprises Inc 320282 fo...

Страница 4: ...nd close the faucet handle to relieve system of water 4 Wipe inside of faucet body with a mild dishwashing soap and hot water 5 Do the same to handle cap and seat cup 6 Reinstall assembly to faucet bo...

Страница 5: ...tion with 200 ppm available chlorine can be made by adding oz 1 tablespoon of regular household bleach 6 sodium hypochlorite solution per gallon of water Do s and Don ts OPERATION 1 Do fully activate...

Страница 6: ...ater only no product 1 Concentrate BIB empty 2 Product hose clogged 3 Product hose kinked 4 Check valve not seating 5 Adjustment screw in too far 1 Load new BIB 2 Clean product hose or replace 3 Check...

Страница 7: ...n For Postmix Beverage Dispenser With Low Pressure Faucet Remove Top Cover Remove Product And Hang Over Sides Of Dispenser Loosen Screw Slide Access Panel Toward Front And Remove After Access Panel Is...

Страница 8: ...l Counter Clockwise For Stronger Mixture Or Clockwise For Leaner Mixture Make small adjustments approximately 1 points or 1 8 turn at a time After Adjustments Are Made Replace Access Panel Tighten Scr...

Страница 9: ...Part No 803171 Issued 3 28 13 Rev 011515 9...

Страница 10: ...Part No 803171 Issued 3 28 13 Rev 011515 10...

Страница 11: ...Part No 803171 Issued 3 28 13 Rev 011515 11 Additional Parts 14410 Black Plastic Cover Small 803197 Drip Tray S S Grid...

Страница 12: ...dial plate after the dial knob is removed This area is now open for cleaning and troubleshooting When reassembling dial knob to shaft be sure that the white indicator is in the same position as befor...