background image

                                                                                       Part No. 803171 Issued 3-28-13   Rev 011515 

 

PROBLEM

 

CAUSE

 

CORRECTIVE ACTION

 

Difficulty priming dispenser.

 

1.   Product adjustment screw 

turned in too far.

 

1.   Turn adjustment dial ¼ turn 

C’Clockwise(weaker/ 
stronger)adjustment. 

2.   Regulator adjustment is re- 

quired.  Call the factory for 
assistance.

 

Pulled faucet handle, no 
product, no water.

 

1.   Water supply not on.

 

1. Turn water supply on.

 

Drink too foamy or bubbly

 

1.   Concentrate BIB empty. 
2.   Hole or tear in product 

tubing  prior to BIB 
connection. 

3.   Loose syrup line connection.

 

1.  Load new BIB 
2.   Replace tubing 
3.   Check syrup line 

connections from check 
valve.

 

Drink inconsistent

 

1.   Waterline pressure dropping 

below machine’s preset 
pressure regulator 
adjustment.

 

2.   Regulator adjustment is re- 

quired.  Call the factory for 
assistance.

 

Water only—no product

 

1.   Concentrate BIB empty. 
2.   Product hose clogged. 
3.   Product hose kinked. 
4.   Check valve not seating. 
5.   Adjustment screw in too far.

 

1.  Load new BIB. 
2.  Clean product hose or 

replace. 

3.  Check for kinks. 
4.   Disassemble and clean check 

valve. 

5.   Turn adjustment screw out 

using adjustment dial.

 

Faucet dripping

 

1.   Foreign particles on seat 

cup. 

2.   Damaged seat cup. 
3.   Pressure set too high.

 

1.  Follow seat cup cleaning. 
2.   Replace seat cup. 
3.   Regulator adjustment is 

required.  Call the factory for 
assistance.

 

Drink too weak

 

1.   Adjustment screw in too far. 
2.   Check valve not seating.

 

1.   Turn adjustment screw out 

Weaker/Stronger adjustment. 

2.   Disassemble and clean check 

valve.

 

Air bubbles in syrup

 

1.   Loose tubing connection at 

QCD or at check valve barb. 

2.   Worn O-ring on QCD 

plunger. 

3.  Air in bag.

 

1.   Ensure tubing is slid all the 

way on to the QCD and 
check valve barb. 

2.   Replace QCD. 
3.   Stand BIB upright, open 

faucet  handle  and  prime 
syrup line until all air 
bubbles are gone.

 

Содержание 872B

Страница 1: ...h the water A built in water pressure regulator ensures the proper amount of syrup is being mixed with the proper amount of water This built in pressure regulator is factory adjusted for a static pres...

Страница 2: ...fitting on rear of dispenser Fitting may vary 4 Turn on the water source to the dispenser 5 Turn the yellow handle to the ON position to allow water to flow through the urn Product Loading 1 Open the...

Страница 3: ...unit or when changing product Flush should be performed at least once a week Note Cleaning requires the use of a cleaning flush adapter An adapter may be purchased from Newco Enterprises Inc 320282 fo...

Страница 4: ...nd close the faucet handle to relieve system of water 4 Wipe inside of faucet body with a mild dishwashing soap and hot water 5 Do the same to handle cap and seat cup 6 Reinstall assembly to faucet bo...

Страница 5: ...tion with 200 ppm available chlorine can be made by adding oz 1 tablespoon of regular household bleach 6 sodium hypochlorite solution per gallon of water Do s and Don ts OPERATION 1 Do fully activate...

Страница 6: ...ater only no product 1 Concentrate BIB empty 2 Product hose clogged 3 Product hose kinked 4 Check valve not seating 5 Adjustment screw in too far 1 Load new BIB 2 Clean product hose or replace 3 Check...

Страница 7: ...n For Postmix Beverage Dispenser With Low Pressure Faucet Remove Top Cover Remove Product And Hang Over Sides Of Dispenser Loosen Screw Slide Access Panel Toward Front And Remove After Access Panel Is...

Страница 8: ...l Counter Clockwise For Stronger Mixture Or Clockwise For Leaner Mixture Make small adjustments approximately 1 points or 1 8 turn at a time After Adjustments Are Made Replace Access Panel Tighten Scr...

Страница 9: ...Part No 803171 Issued 3 28 13 Rev 011515 9...

Страница 10: ...Part No 803171 Issued 3 28 13 Rev 011515 10...

Страница 11: ...Part No 803171 Issued 3 28 13 Rev 011515 11 Additional Parts 14410 Black Plastic Cover Small 803197 Drip Tray S S Grid...

Страница 12: ...dial plate after the dial knob is removed This area is now open for cleaning and troubleshooting When reassembling dial knob to shaft be sure that the white indicator is in the same position as befor...

Отзывы: