Part No. 803171 Issued 3-28-13 Rev 011515
6
PROBLEM
CAUSE
CORRECTIVE ACTION
Difficulty priming dispenser.
1. Product adjustment screw
turned in too far.
1. Turn adjustment dial ¼ turn
C’Clockwise(weaker/
stronger)adjustment.
2. Regulator adjustment is re-
quired. Call the factory for
assistance.
Pulled faucet handle, no
product, no water.
1. Water supply not on.
1. Turn water supply on.
Drink too foamy or bubbly
1. Concentrate BIB empty.
2. Hole or tear in product
tubing prior to BIB
connection.
3. Loose syrup line connection.
1. Load new BIB
2. Replace tubing
3. Check syrup line
connections from check
valve.
Drink inconsistent
1. Waterline pressure dropping
below machine’s preset
pressure regulator
adjustment.
2. Regulator adjustment is re-
quired. Call the factory for
assistance.
Water only—no product
1. Concentrate BIB empty.
2. Product hose clogged.
3. Product hose kinked.
4. Check valve not seating.
5. Adjustment screw in too far.
1. Load new BIB.
2. Clean product hose or
replace.
3. Check for kinks.
4. Disassemble and clean check
valve.
5. Turn adjustment screw out
using adjustment dial.
Faucet dripping
1. Foreign particles on seat
cup.
2. Damaged seat cup.
3. Pressure set too high.
1. Follow seat cup cleaning.
2. Replace seat cup.
3. Regulator adjustment is
required. Call the factory for
assistance.
Drink too weak
1. Adjustment screw in too far.
2. Check valve not seating.
1. Turn adjustment screw out
Weaker/Stronger adjustment.
2. Disassemble and clean check
valve.
Air bubbles in syrup
1. Loose tubing connection at
QCD or at check valve barb.
2. Worn O-ring on QCD
plunger.
3. Air in bag.
1. Ensure tubing is slid all the
way on to the QCD and
check valve barb.
2. Replace QCD.
3. Stand BIB upright, open
faucet handle and prime
syrup line until all air
bubbles are gone.
Содержание 872B
Страница 9: ...Part No 803171 Issued 3 28 13 Rev 011515 9...
Страница 10: ...Part No 803171 Issued 3 28 13 Rev 011515 10...