OPERATION 

 

This  section of the manual is to help you get the maximum  efficiency and maximum smoke 
(particulate) reduction from your  heater.   If you should experience any difficulty or 
have  any  questions concerning your heater, contact your dealer for assistance.  The 
manufacturer  recommends that  for maximum performance burn dried natural seasoned hard 
wood. 
 

Build a fire for maximum efficiency.

  These models burn wood and extract heat so efficiently, 

a large fire is not  necessary.  A large fire not only wastes energy, it usually results in the home 
being too warm for comfort. 
 
The following steps will serve as a guide for operating your stove. 

 

BUILDING A FIRE 

 
1.  Open the door. 
2.  Open the primary air control under hearth, push in.  To close pull all the way out. 
3.  Twist two pieces of non-colored newspaper into a roll and place them on the floor of the 

firebox. 

4.  These models are not designed for the use of grates, andirons or other methods of supporting 

the fuel. 

NOTE:  “Do not use grate or elevate fire.  Build wood fire directly on inner bottom of fire box.”

 

5.  Lay several pieces of dry kindling on top of the newspaper. 
6.  Place three or four small pieces of firewood, 2-3" in diameter, on top of the kindling. 
7.  Light the newspaper in the front. Close and latch the door. Don't leave the fire unattended at 

this point.  The draft   system of the heater should start quickly.  It may be necessary to 
preheat the chimney to get the draft started.  To do this, open the door and add newspaper to 
the top rear of the wood.  Light or let this paper ignite and allow to burn while holding the 
door slightly cracked.  Once the draft has started, close and lock the door.  You are over 
heating the unit if the chimney and or connector glows red. 

8. 

After embers and a coal bed  have been established, load the heater with dried 
natural seasoned hard wood.

 

 

NOTE:  THE FUELING DOOR MUST REMAIN CLOSED DURING OPERATION.

 

NOTE:  If the optional blower is being used on the Model FS21. Your stove is equipped 

with a automatic thermostat.  When the stove gets hot enough, the thermostat 
will activate the room air blower.  Set fan speed according to desired heat output.   

NOTE:  When refueling or removing ashes turn “OFF” room air blower. Be sure to turn 

room air blower back on when finished. 

NOTE:  Do not run power cord underneath heater, or in walk way or heavy traffic areas.  

 

SECTION IV 

 

Содержание FS 21

Страница 1: ...INSTRUCTIONS CONTACT THE AUTHORITY HAVING JURISDICTION SUCH AS MUNICIPAL BUILDING DEPARTMENT FIRE DEPARTMENT FIRE PREVENTION BUREAU etc CONSULT BEFORE INSTALLATION TO DETERMINE THE NEED TO OBTAIN A PE...

Страница 2: ......

Страница 3: ...8 C Vertical Exit Using DVL Close Clearance Pipe Listed 2100 UL 103 HT chimney with Close Clearance Pipe Shields 10 D Vertical Wall Exit Using DVL Close Clearance Pipe and Elbow Listed 2100 UL 103 HT...

Страница 4: ...s in your home The Model FS 21 is approved for use in specified Pre Fabricated fireplaces ZCF s Use the list on Page 11 or contact your dealer for additional units Examine the masonry fireplace and ch...

Страница 5: ...to the firebox through the secondary air tubes at the top of the firebox This secondary air burns the impurities in the smoke released from the initial wood burning The temperature necessary for this...

Страница 6: ...motor is being used Do not run power cord under unit or in high traffic areas 3 Check the primary air draft control to ensure that it slides freely 4 Remove any items from within the firebox Chimney...

Страница 7: ...the overall R value of the system is grater than the R value of the specified floor protec tor the alternate is acceptable Example The specified floor protector should be 3 4 thick material with a K...

Страница 8: ...Exit using 6 Single wall minimum 24 ga blued or black pipe and any Listed 2100 UL 103 HT Chimney Without optional close clearance shield and pipe shield NOTE For minimum clearances See Page 7 Figure...

Страница 9: ...24 ga blued or black pipe and minimum floor protector The clearances above may be reduced Follow NFPA 211 codes if available or follow instructions on Pages 10 and 11 C C C C Figure 3 SINGLE WALL CON...

Страница 10: ...ition and project a point onto the plumb line level with the center of the elbow 3 Measure up so there will be at least 1 4 rise per foot of horizontal connector pipe maintaining clearances to the cei...

Страница 11: ...th elbow and minimum floor protector Clearances above may be reduced Follow NFPA 211 codes if available or follow instructions on Pages 12 and 13 Figure 4 A B C D E F G MODEL 21 25 13 13 15 5 8 6 16 S...

Страница 12: ...exit A small weight on a string will serve as a plumb bob Mark the ceiling where the string is suspended to locate the center of the chimney 2 After locating the center of the hole install the ceilin...

Страница 13: ...ALL BUCK STOVE LISTED 2100 UL 103 HT TYP CHIMNEY RADIATION SHIELD LISTED 2100 UL 103 HT TYP CHIMNEY DVL CLOSE CLEARANCE PIPE NOTE See Page 22 for installation of optional close clearance shields and p...

Страница 14: ...ce Pipe maintain manufacturer s minimum clearances between pipe and ceiling 2 Place the vertical portion of the heater pipe and the elbow in position and project a point onto the plumb line level with...

Страница 15: ...or Figure 8 A B C D E F G MODEL 21 19 7 7 8 5 8 6 16 DVL CLOSE CLEARANCE PIPE IN SIDE WALL CEILING Maintain 18 Minimum Clearance WALL PASS THROUGH CONNECTOR CENTER LINE OF ELBOW MARK PLUMB LINE ON WAL...

Страница 16: ...ate two holes in bottom of base for securing the pedestal to pad and floor and mark holes location on pad See Figure 10A Place heater out of the way of the installation area 8 Now use a 3 8 masonry bi...

Страница 17: ...HEN MOBILE HOME IS NOT UNDERPINNED Figure 10C 4 10x1 OUTSIDE AIR DUCT THROUGH UNDERPINNED 24 min 610 mm OUTSIDE AIR DUCT THROUGH FLOOR WHEN MOBLE HOME IS NOT UNDERPENNED RAIN CAP FLASHING RADIATION SH...

Страница 18: ...rom the front of the stove Smoking usually indicates a defective or poorly positioned chimney Some chimneys with a marginal draft can be preheated by lighting newspaper and holding it near the open da...

Страница 19: ...s being used Do not run power cord under unit or in high traffic areas 3 Check the primary air draft control to ensure that it slides freely 4 Remove any items from within the firebox Chimney This mod...

Страница 20: ...the overall R value of the system is grater than the R value of the specified floor protec tor the alternate is acceptable Example The specified floor protector should be 3 4 thick material with a K...

Страница 21: ...serve as a plumb bob Mark the ceiling where the string is suspended to locate the center of the chimney 2 After locating the center of the hole install the ceiling support box chimney or chimney conne...

Страница 22: ...and minimum floor protector A B C D E F G H MODEL 21 19 7 84 8 5 8 6 16 48 BUCK STOVE C Figure 12 CEILING SUPPORT CEILING INSTALLATION FLASHING CONTEMPORARY CAP STORM COLLAR DO NOT OBSTRUCT CAULK NEW...

Страница 23: ...rom the front of the stove Smoking usually indicates a defective or poorly positioned chimney Some chimneys with a marginal draft can be preheated by lighting newspaper and holding it near the open da...

Страница 24: ...TURE BELOW 3 Drill two 2 3 16 holes in the sides of the stove where the shield meets the front side Insert two 2 3 8 self tapping screws SEE PICTURE BELOW 4 Next loosen two 2 top screws holding side s...

Страница 25: ...ral pieces of dry kindling on top of the newspaper 6 Place three or four small pieces of firewood 2 3 in diameter on top of the kindling 7 Light the newspaper in the front Close and latch the door Don...

Страница 26: ...ERSED THEY DISPOSED OF BY BURIAL IN SOIL OR FINAL DISPOSAL IF THE ASHES ARE ALL COMBUSTIBLE MATERIALS PENDING OR ON THE GROUND WELL AWAY FROM CLOSED CONTAINER OF ASHES SHOULD WITH A TIGHT FITTING LID...

Страница 27: ...OSITION IS AT THE 8 O CLOCK POSITION AND LOW IS AT THE 4 O CLOCK POSITION MOUNT RHEOSTAT BY PLACING IT BEHIND HEARTH SUPPORT WITH WIRES ON BOTTOM SIDE PLACE PLASTIC STUD THROUGH HOLE IN BRACKET AND SE...

Страница 28: ...Page 26 STEP 1 STEP 2 STEP 3 WIRE DIAGRAM...

Страница 29: ...BLACK FLAT GASKET WITH ADHESIVE 1 JUMPER WIRE 4 MALE FEMALE TERMINAL 1 110 THERMOSTAT 1 RHEOSTAT 1 RHEOSTAT NUT 1 RHEOSTAT INDICATOR KNOB 1 RHEOSTAT LABEL 1 POWER CORD 1 STRAIN RELIEF 1 6 WIRE TIE 1...

Страница 30: ...lower running DISPOSAL OF ASHES Ashes should be placed in a metal container with a tight fitting lid The closed container of ashes should be placed on a noncombustible floor or on the ground well away...

Страница 31: ...draft or inlet air a Close inlet air control as much as possible to maintain desired heat output b Check gaskets reinstall fiberglass gasket around doors and glass as necessary Improper door fitting...

Страница 32: ...ransportation charges required Thereafter B Period II For the period after the first year from the date of purchase and extending for five years as long as the Buck Stove is owned by the original purc...

Страница 33: ...this warranty must be performed by an authorized Buck Stove service representative Repairs or attempted repairs by anyone other than an authorized service representative are not covered under this wa...

Отзывы: