background image

Page 30 

 

NEW BUCK CORPORATION (NBC) 

"LIMITED WARRANTY" FOR THE BUCK STOVE 

PLEASE READ THIS WARRANTY CAREFULLY 

 

PRODUCTS COVERED

 

 

This  warranty  covers the new Buck  Stove  heating unit, so long as it is owned by the original 
purchaser,  including  optional  and  standard   accessories purchased at the same time, subject to 
terms, limitations, and conditions herein set out. 
 
PRODUCTS NOT COVERED 

 

This warranty does not cover the following: 
Glass, Refractory material  or  firebrick, Gaskets. 
 
This Warranty will not cover any damage and/or failure  caused by abuse or improper 
installation  of  the products covered. 
 

WARRANTY TIME PERIODS 

(A) 

Period I

 

For  one year from the date of purchase,  NBC  will replace or repair, at its option, any 
part  defective in materials or workmanship.  The costs of parts only are included.  The 
customer pays any labor or  transportation charges required.  
 
Thereafter, 

(B) 

Period II

 

For  the period after the first year from the  date of purchase and extending for five years as 
long as  the Buck  Stove is owned by the original  purchaser,  NBC will repair  or  replace, at 
its  option,  any  part defective  in  materials  or  workmanship,  with  the exception  of:  
electrical motors, wiring,  switches, and  components: optional and standard  accessories; 
and all parts not permanently attached to the heating unit.  Parts not permanently attached to 
the  heating unit  are defined as those items designed to  be  removed from the stove, 
including those removable  with common  hand  tools. The costs of  parts  only  are 
included. The customer pays any labor or transportation charges required.   

                                      .

 

PROCEDURE 

Should you feel that your BUCK STOVE is defective, you should contact any Buck Stove 
dealer for the name of your nearest authorized Buck Stove service  representative, who will 
instruct you on the proper procedure, depending on which Warranty Time Period (Period I or 
Period II) applies. 
     
 
 

Содержание FS 21

Страница 1: ...INSTRUCTIONS CONTACT THE AUTHORITY HAVING JURISDICTION SUCH AS MUNICIPAL BUILDING DEPARTMENT FIRE DEPARTMENT FIRE PREVENTION BUREAU etc CONSULT BEFORE INSTALLATION TO DETERMINE THE NEED TO OBTAIN A PE...

Страница 2: ......

Страница 3: ...8 C Vertical Exit Using DVL Close Clearance Pipe Listed 2100 UL 103 HT chimney with Close Clearance Pipe Shields 10 D Vertical Wall Exit Using DVL Close Clearance Pipe and Elbow Listed 2100 UL 103 HT...

Страница 4: ...s in your home The Model FS 21 is approved for use in specified Pre Fabricated fireplaces ZCF s Use the list on Page 11 or contact your dealer for additional units Examine the masonry fireplace and ch...

Страница 5: ...to the firebox through the secondary air tubes at the top of the firebox This secondary air burns the impurities in the smoke released from the initial wood burning The temperature necessary for this...

Страница 6: ...motor is being used Do not run power cord under unit or in high traffic areas 3 Check the primary air draft control to ensure that it slides freely 4 Remove any items from within the firebox Chimney...

Страница 7: ...the overall R value of the system is grater than the R value of the specified floor protec tor the alternate is acceptable Example The specified floor protector should be 3 4 thick material with a K...

Страница 8: ...Exit using 6 Single wall minimum 24 ga blued or black pipe and any Listed 2100 UL 103 HT Chimney Without optional close clearance shield and pipe shield NOTE For minimum clearances See Page 7 Figure...

Страница 9: ...24 ga blued or black pipe and minimum floor protector The clearances above may be reduced Follow NFPA 211 codes if available or follow instructions on Pages 10 and 11 C C C C Figure 3 SINGLE WALL CON...

Страница 10: ...ition and project a point onto the plumb line level with the center of the elbow 3 Measure up so there will be at least 1 4 rise per foot of horizontal connector pipe maintaining clearances to the cei...

Страница 11: ...th elbow and minimum floor protector Clearances above may be reduced Follow NFPA 211 codes if available or follow instructions on Pages 12 and 13 Figure 4 A B C D E F G MODEL 21 25 13 13 15 5 8 6 16 S...

Страница 12: ...exit A small weight on a string will serve as a plumb bob Mark the ceiling where the string is suspended to locate the center of the chimney 2 After locating the center of the hole install the ceilin...

Страница 13: ...ALL BUCK STOVE LISTED 2100 UL 103 HT TYP CHIMNEY RADIATION SHIELD LISTED 2100 UL 103 HT TYP CHIMNEY DVL CLOSE CLEARANCE PIPE NOTE See Page 22 for installation of optional close clearance shields and p...

Страница 14: ...ce Pipe maintain manufacturer s minimum clearances between pipe and ceiling 2 Place the vertical portion of the heater pipe and the elbow in position and project a point onto the plumb line level with...

Страница 15: ...or Figure 8 A B C D E F G MODEL 21 19 7 7 8 5 8 6 16 DVL CLOSE CLEARANCE PIPE IN SIDE WALL CEILING Maintain 18 Minimum Clearance WALL PASS THROUGH CONNECTOR CENTER LINE OF ELBOW MARK PLUMB LINE ON WAL...

Страница 16: ...ate two holes in bottom of base for securing the pedestal to pad and floor and mark holes location on pad See Figure 10A Place heater out of the way of the installation area 8 Now use a 3 8 masonry bi...

Страница 17: ...HEN MOBILE HOME IS NOT UNDERPINNED Figure 10C 4 10x1 OUTSIDE AIR DUCT THROUGH UNDERPINNED 24 min 610 mm OUTSIDE AIR DUCT THROUGH FLOOR WHEN MOBLE HOME IS NOT UNDERPENNED RAIN CAP FLASHING RADIATION SH...

Страница 18: ...rom the front of the stove Smoking usually indicates a defective or poorly positioned chimney Some chimneys with a marginal draft can be preheated by lighting newspaper and holding it near the open da...

Страница 19: ...s being used Do not run power cord under unit or in high traffic areas 3 Check the primary air draft control to ensure that it slides freely 4 Remove any items from within the firebox Chimney This mod...

Страница 20: ...the overall R value of the system is grater than the R value of the specified floor protec tor the alternate is acceptable Example The specified floor protector should be 3 4 thick material with a K...

Страница 21: ...serve as a plumb bob Mark the ceiling where the string is suspended to locate the center of the chimney 2 After locating the center of the hole install the ceiling support box chimney or chimney conne...

Страница 22: ...and minimum floor protector A B C D E F G H MODEL 21 19 7 84 8 5 8 6 16 48 BUCK STOVE C Figure 12 CEILING SUPPORT CEILING INSTALLATION FLASHING CONTEMPORARY CAP STORM COLLAR DO NOT OBSTRUCT CAULK NEW...

Страница 23: ...rom the front of the stove Smoking usually indicates a defective or poorly positioned chimney Some chimneys with a marginal draft can be preheated by lighting newspaper and holding it near the open da...

Страница 24: ...TURE BELOW 3 Drill two 2 3 16 holes in the sides of the stove where the shield meets the front side Insert two 2 3 8 self tapping screws SEE PICTURE BELOW 4 Next loosen two 2 top screws holding side s...

Страница 25: ...ral pieces of dry kindling on top of the newspaper 6 Place three or four small pieces of firewood 2 3 in diameter on top of the kindling 7 Light the newspaper in the front Close and latch the door Don...

Страница 26: ...ERSED THEY DISPOSED OF BY BURIAL IN SOIL OR FINAL DISPOSAL IF THE ASHES ARE ALL COMBUSTIBLE MATERIALS PENDING OR ON THE GROUND WELL AWAY FROM CLOSED CONTAINER OF ASHES SHOULD WITH A TIGHT FITTING LID...

Страница 27: ...OSITION IS AT THE 8 O CLOCK POSITION AND LOW IS AT THE 4 O CLOCK POSITION MOUNT RHEOSTAT BY PLACING IT BEHIND HEARTH SUPPORT WITH WIRES ON BOTTOM SIDE PLACE PLASTIC STUD THROUGH HOLE IN BRACKET AND SE...

Страница 28: ...Page 26 STEP 1 STEP 2 STEP 3 WIRE DIAGRAM...

Страница 29: ...BLACK FLAT GASKET WITH ADHESIVE 1 JUMPER WIRE 4 MALE FEMALE TERMINAL 1 110 THERMOSTAT 1 RHEOSTAT 1 RHEOSTAT NUT 1 RHEOSTAT INDICATOR KNOB 1 RHEOSTAT LABEL 1 POWER CORD 1 STRAIN RELIEF 1 6 WIRE TIE 1...

Страница 30: ...lower running DISPOSAL OF ASHES Ashes should be placed in a metal container with a tight fitting lid The closed container of ashes should be placed on a noncombustible floor or on the ground well away...

Страница 31: ...draft or inlet air a Close inlet air control as much as possible to maintain desired heat output b Check gaskets reinstall fiberglass gasket around doors and glass as necessary Improper door fitting...

Страница 32: ...ransportation charges required Thereafter B Period II For the period after the first year from the date of purchase and extending for five years as long as the Buck Stove is owned by the original purc...

Страница 33: ...this warranty must be performed by an authorized Buck Stove service representative Repairs or attempted repairs by anyone other than an authorized service representative are not covered under this wa...

Отзывы: