Page 4
SECTION II
RESIDENTIAL INSTALLATION OF GAS LOGS
FIREPLACE PREPARATION
The fireplace needs to be prepared before installing the gas logs.
A. Turn off the gas supply to the fireplace.
B. Any outside air ducts on the fireplace shall be permanently closed at the time of the appliance
installation.
“
WARNING: BEFORE INSTALLING IN A SOLID FUEL BURNING FIREPLACE, THE
CHIMNEY FLUE AND FIREBOX MUST BE CLEANED OF SOOT, CREOSOTE, ASHES
AND LOOSE PAINT BY A QUALIFIED CHIMNEY CLEANER.”
“
WARNING: DO NOT ALLOW FANS TO BLOW DIRECTLY INTO THE FIREPLACE.
AVOID ANY DRAFTS THAT ALTER BURNER FLAME PATTERN.”
LOCATION
Centrally
locate the gas logs in the fireplace. Place them
deep enough into the fireplace to
accomplish adequate draft (if use as a vented gas log set is planned). Ensure that the front of the logs
sit inside the front edge of the fireplace.
For your convenience, we have furnished two holes in the rear bottom bar of the burner base to fasten
it to the floor if you deem it necessary.
NOTE: IF THE EXISTING FIREPLACE IS EQUIPPED WITH A SCREEN IT MUST BE IN PLACE
WHEN THE APPLIANCE IS OPERATING. THE SCREEN SHALL HAVE ADEQUATE OPENING
(S) FOR INTRODUCTION OF AIR FOR COMBUSTION AND VENTILATION.
NOTE: MAINTAIN PROPER CLEARANCE FOR PURPOSE OF SERVICING, PROPER
INSTALLATION, AND OPERATION.
NOTE: WHEN THE APPLIANCE IS INSTALLED ON CARPETING, TILE OR OTHER
COMBUSTIBLE MATERIAL, OTHER THAN WOOD FLOORING, THE APPLIANCE SHALL BE
INSTALLED ON A METAL OR WOOD PANEL EXTENDING THE FULL WIDTH AND DEPTH OF
THE APPLIANCE.
* WARNING: Canopy model number MAPSFPC must be used at the fire-
place opening. (Can be obtained from your local dealer or purchased from
the factory.)
Mantel Minimum Clearances for a listed Zero Clearance Firebox or a Masonry Fireplace.
Minimum Clearances Without Canopy
Minimum Clearances With Canopy
DISCRIPTION
DATE
REV.
BY
APRVD
J.GLENN
2-2-00
11 GA. C.R.
UPPER HEAT SHIELD
M.BEASTON
N.T.S.
21 1/2" X 9 1/2"
22
PS220012
NEW RELEASE
M.B.
DATE
4”
17”
0” To 6”
WALL
ANGLED MANTEL
19”
19”
6” To 10”
10” To 12”
WALL
FLAT MANTEL
4”
18”
20”
21”
0” To 6”
6” To 10”
10” To 12”
WALL
FLAT MANTEL
21”
21”
21”
0” To 6”
6” To 10”
10” To 12”
Figure 1.