5.  Two models are available.  One specific model for propane (LP), and one for natural gas.
Use the correct gas type for your home.  This unit is not field convertible.

6.  If these gas logs are for use with propane gas, do not place propane supply tank(s) inside
any structure. Locate propane supply tank(s) outdoors.

7.  If you smell gas:

-Shut off gas supply.
-Do not try to light any appliance.
-Do not touch any electrical switch; do not use any phone in your building.
-Immediately call your gas supplier from a neighbor's phone. Follow the gas supplier's

instructions.

-If you cannot reach your gas supplier, call the fire department.

8. "This heater shall  not  be  installed  in  unusually  tight  construction  unless  provisions  are
provided  for  adequate  air  for  combustion  and  ventilation  ."    See  Section  V -

“Producing

Adequate  Air For Combustion And Ventilation”,

page 20.

9. Surface  of    gas  logs  becomes  very  hot  when  operating.

Keep  children  and  adults  away

from hot surface.   Gas logs will remain hot for some time after shutdown.  Allow surface to
cool before touching.
10. Never place any objects on these gas logs.
11. These gas logs MUST  NOT  BE  USED with  glass doors in the closed position.
12. If equipped, fresh air damper must be closed permanently.
13.  Keep  appliance  area  clean  and  free  from  combustible materials, gasoline, and  other
flammable  vapors

and

liquids.

Keep  burner

and

control

compartment

clean. See Installation and Operating Instructions accompanying heater.
14. If  burner  shuts  off, do  not  relight until you provide fresh outside air.  If burner keeps
shutting off, have unit serviced.
15.  An unvented room heater having input rating of more than 10,000 BTU per hour shall not
be installed in a bedroom or bathroom.
16.  Maintain clearance around air openings.

WARNING

This appliance is equipped for (natural or propane) gas.
Field conversion is not permitted.

Содержание EMBER VISION 100 SERIES

Страница 1: ...supplier from a neighbor s phone Follow the gas supplier s instructions If you cannot reach the gas supplier call the fire department Installation and service must be performed by a qualified installe...

Страница 2: ......

Страница 3: ...SECTION III Installation Heat Shield 16 Wiring Diagram 18 SECTION IV Installation After Market Mobile Home 20 SECTION V Producing Adequate Air For Combustion And Ventilation 20 Ventilation Air For Co...

Страница 4: ......

Страница 5: ...nry fireplace or U L listed pre fabricated fireplace constructed of non combustible materials 2 The installation must conform with local codes or in the absence of local codes with the National Fuel G...

Страница 6: ...ustion And Ventilation page 20 9 Surface of gas logs becomes very hot when operating Keep children and adults away from hot surface Gas logs will remain hot for some time after shutdown Allow surface...

Страница 7: ...as logs be kept clean and clear 23 Do not use these gas logs for burning trash or cooking Never place matches paper garbage or any other material on top of logs or into the flames 24 Do not install or...

Страница 8: ...ar of the burner base to fasten it to the floor if you deem it necessary NOTE IF THE EXISTING FIREPLACE IS EQUIPPED WITH A SCREEN IT MUST BE IN PLACE WHEN THE APPLIANCE IS OPERATING THE SCREEN SHALL H...

Страница 9: ...place opening MINIMUM FIREPLACE DIMENSIONS FOR EMBER VISION 100 AND 200 SERIES LOG SET MANUFACTURED BY NEW BUCK CORPORATION FOR SOLID FUEL BURNING FIREPLACE OR MASONRY FIREPLACE AND PREFAB OR MANUFACT...

Страница 10: ...ight Top Middle log 4 on the pins located on the right top section of Middle log 2 5 Place Left Front log 5 on the locator pins located on the left middle section of the front burner pan 6 Place Right...

Страница 11: ...lt in property damage or personal injury DISCRIPTION DATE REV BY APRVD 1 7 LOG PLACEMENT FOR EMBER VISION 100 SERIES 24 LOG SET OAK LOGS SHOWN Apply loose material per instructions manual DO NOT apply...

Страница 12: ...t in property damage or personal injury Apply loose material per instructions manual DO NOT apply extra material or material not sup plied with the heater Replace only with material from your Buck Sto...

Страница 13: ...lt in property damage or personal injury DISCRIPTION DATE REV BY APRVD 1 7 LOG PLACEMENT FOR EMBER VISION 200 SERIES 30 LOG SET OAK LOGS SHOWN Apply loose material per instructions manual DO NOT apply...

Страница 14: ...s Natural Propane LP Maximum Heat Input 40 000 40 000 Minimum Heat Input 31 000 33 000 Gas Inlet Pressure Maximum 10 5 ins W C 13 0 ins W C Minimum 4 5 ins W C 10 5 ins W C Manifold Pressure 3 5 ins W...

Страница 15: ...ctions B BEFORE LIGHTING smell all around the appliance area for gas Be sure to smell next to the floor because some gas is heavier than air and will settle to the floor WHAT TO DO IF YOU SMELL GAS Do...

Страница 16: ...rol knob pressed in push down in and release the ignitor button ignitor button is located on the left hand side of the front of the appliance This will light the pilot If needed keep repeating this st...

Страница 17: ...f the pilot will not stay lit after several tries turn the gas control knob to OFF and call your service technician or gas supplier 10 Turn control knob counterclockwise to ON 11 If using unit without...

Страница 18: ...d lighter rod 2 Place the match in the holder and light With the left hand depress the control knob counterclockwise to PILOT Hold in 3 Take rod and light match and ignite pilot The pilot is located b...

Страница 19: ...on middle log NATURAL PROPANE WHEN USED AS A HEATING APPLIANCE HEAT OUTPUT The heat output into the room can be controlled by the position of the flue damper when used as vented gas logs See Section V...

Страница 20: ...8 NOTE When using Ember Vision 100 Series Log Set with optional Heat Shield the following minimums must be met Front 34 Rear 31 Height 20 Depth 20 1 2 NOTE When using Ember Vision 200 Series Log Set w...

Страница 21: ...HS Always include correct name part number and model number of the heater when ordering service parts KEY PART DESCRIPTION PART NUMBER 1 BLOWER PE A2 40 01 Rating 120 volts 60HZ 54 Amps 2 110 THERMOST...

Страница 22: ...t must be replaced with a wire of at least a 105o C temperature rating NOTE Installation and repair should be done by a qualified service person This heater should be inspected before use and at least...

Страница 23: ...OR YOUR PROTECTION AGAINST SHOCK HAZARD AND SHOULD BE PLUGGED DIRECTLY INTO A PROPERLY GROUNDED THREE PRONG RECEPTACLE WARNING Do not use a blower insert heat exchanger insert or other accessories not...

Страница 24: ...liances installed in that space Rooms communicating directly with the space in which the appliances are installed through openings not furnished with doors are considered a part of the unconfined spac...

Страница 25: ..._____cu ft volume of space EXAMPLE 20 ft Length x 16 ft Width x 8 ft ceiling Height 2560 cu ft volume of space If additional ventilation to adjoining room is supplied with grills or openings add the v...

Страница 26: ...han the maximum BTU Hr the space can support You must provide additional fresh air Your options are as follows A Rework worksheet adding the space of an adjoining room If the extra space provides an u...

Страница 27: ...ING REWORK WORKSHEET ADDING THE SPACE OF THE ADJOINING UNCONFINED SPACE THE COMBINED SPACES MUST HAVE ADEQUATE AMOUNT AIR TO SUPPLY ALL APPLIANCES IN BOTH SPACES NOTE Each opening shall have a minimum...

Страница 28: ...Combustion and Ventilation for required size of ventilation grills or ducts IMPORTANT Do not provide openings for inlet air into attic if attic has a thermostat controlled power vent Heated air enter...

Страница 29: ...per flap from the damper opening NOTE See chart on page 26 MINIMUM FIREPLACE DIMENSIONS FOR EMBER VISION 100 AND 200 LOG SET MANUFACTURED BY NEW BUCK CORPORATION FOR SOLID FUEL BURNING FIREPLACE OR MA...

Страница 30: ...See GAS PRESSURE CHECK page 10 6 See OPERATING INSTRUCTIONS pages 11 13 7 See BURNER PILOT FLAME CHECK for proper flame pattern page 15 8 See CLEANING INSTRUCTIONS page 27 NOTE Visually check the pil...

Страница 31: ...EPLACE AS DESCRIBED IN THESE INSTRUCTIONS IT SHOULD NOT BE USED FOR ANY OTHER PURPOSE CLEANING CAUTION BEFORE CLEANING OR MOVING LOGS OR OTHER PARTS OF THE HEATER BE SURE TO READ THE ABOVE SECTION ON...

Страница 32: ...rn control knob to PILOT position 3 Press in control knob while in PILOT position TROUBLESHOOTING WARNING TURN OFF UNPLUG HEATER AND LET COOL BEFORE SERVICING ONLY A QUALIFIED SERVICE PERSON SHOULD SE...

Страница 33: ...ilot flame to go out This problem can be caused by one or both of the following A low gas pressure B dirty or partially clogged ODS PILOT 7 Control valve damaged 4 Continue to hold down control knob R...

Страница 34: ...quipped with this type of valve 2 Air in gas line 3 Air passageways on heater blocked 4 Dirty or partially clogged burner orifice SOLUTION 1 Clean burner see Cleaning and Maintenance or replace burner...

Страница 35: ...ces unwanted odors Heater shuts off in use ODS operates Gas odor even when control knob is in OFF position POSSIBLE CAUSE 1 Metal expands while heating or contracts while cooling 1 Heater burning vapo...

Страница 36: ...stion POSSIBLE CAUSE 1 Foreign matter between control valve and burner 2 Gas Leak See WARNING statement at top of previous page SOLUTION 1 Take apart gas tubing and remove foreign matter 2 Locate and...

Страница 37: ...t Assembly 3 PILOT TUBE 3 16 MF 31612 ALMTUB 4 GENERATOR WIRE Part of Pilot Assembly 5 REAR BURNER PO VE1002 FRONT BURNER PO VE1001 6 INLET ELBOW PH 4966 7 3 8 COMP NUT SLEEVE PH 616 PH 606 8 3 8 BURN...

Страница 38: ...view follows Always include correct name part number and model number of the heater when ordering service parts Please contact your local dealer or distributor when ordering If one is not available y...

Страница 39: ...parts voids this warranty The heater MUST be installed by a qualified installer in accordance with all local codes and instructions furnished with the unit This warranty does not apply to parts that a...

Страница 40: ......

Страница 41: ...777 PLEASE NOTE Owner Registration Card must contain Authorized Buck Stove Dealer Number and Certified Installer s number if applicable for warranty coverage to begin NAME ____________________________...

Отзывы: