Page 16
SECTION III
INSTALLATION OF LOG SET WITH
(OPTIONAL) HEAT SHIELD MODEL 19HS
For installation of gas supply see “Gas Connection”
in Section II, page 5.
NOTE: Centrally locate the Heat Shield in the fireplace and place it deep enough into the
fireplace to accomplish adequate draft (if use as a vented heater is planned). Ensure that the
Heat Shield front is inside the front edge of the fireplace. See Figure 8. Using the screws and
anchor provided, fasten the Heat Shield to the floor of the fireplace. On each side of floor
frame
of Heat Shield base, there is a “go through hole”
.
Position the Heat Shield as
described above. Mark the hole for drilling. See Figure 8.
NOTE:When using Ember Vision 100 Series Log Set with
optional
Heat
Shield
the
following minimums must be met:
Front 34"-Rear 31"-Height 20"-Depth 20 1/2"
NOTE:When using Ember Vision 200 Series Log Set with
optional
Heat
Shield
the
following minimums must be met:
Front 36"-Rear 31"-Height 20"-Depth 20 1/2"
Blower Motor Floor Frame(s)
M a n t e l
Figure 8
“Go Through Holes” for fastening the
19HS to the fireplace floor. Fireplace Heat Shield
To avoid any movement of the gas log set during operation, screw the base to the floor of the
fireplace using the screws provided. Then follow log positioning in Section II.
NOTE: For the first few hours of burning, you will have a paint and burning smell. It is
recommended to leave the fan off during this period.
You may also want to raise a
window or open the doors.
Area For Log
Base Placement
(Center)
“Flush”
Heat Shield
Figure 8.