4081 User Manual
Issue 3
4081 unit ID dip switches
When remotely controlling more than one unit, the ID dip-switches on the
rear of the unit need to be set so that each unit on the chain responds to
the correct commands.
The first 3 switches from left to right are used to set the machine IDs from
1-8.
These switches are On when in the down position (the right-most switch
on this block puts the unit into 'Bootloader Mode' which allows the 4081
firmware to be updated. Please see page 24 for this procedure).
Unit ID
Switch 1
Switch 2
Switch 3
1
Off
Off
Off
2
On
Off
Off
3
Off
On
Off
4
On
On
Off
5
Off
Off
On
6
On
Off
On
7
Off
On
On
8
On
On
On
Where there are more than 8 units on the RS 485 chain, the IDs for units
greater than 8 are set using dip-switch 1 on the switch-block labelled
SW2 inside the unit (with the front of the unit to the left, this switch-block
is just above a white programming connector).
•
With this switch in the down position, the unit will have an ID
between 1 & 8.
•
With this switch in the up position, the unit will have an ID
between 9 & 16.
NB:
Switch 1 is On when in the up position.
Remove the lid to the unit, and set switch 1 to be ON, then set the
switches on the rear of the unit to the following:
fp
Unit ID
Switch 1
Switch 2
Switch 3
9
Off
Off
Off
10
On
Off
Off
11
Off
On
Off
12
On
On
Off
13
Off
Off
On
14
On
Off
On
15
Off
On
On
16
On
On
On
If a unit's ID is changed, the 4081 must be switched off and on again for
the remote control software to be aware of the new ID number.
If the ID number is set incorrectly, a unit will either fail to respond or
multiple units will respond to a single command.
- 29 -
Front of unit
The switch-block will be covered
with a thin protective film which
should be removed first.