4081
Quad Mic Preamp
User Manual
Issue 3
Firmware V2.0 or later
The 4081 is a quad mic / line pre-amplifier, based on the classic 1081 modules
and provides both powerful control and the legendary Neve sound.
Страница 1: ...81 Quad Mic Preamp User Manual Issue 3 Firmware V2 0 or later The 4081 is a quad mic line pre amplifier based on the classic 1081 modules and provides both powerful control and the legendary Neve soun...
Страница 2: ...ect The Power Cord Use Only Accessories Specified By The Manufacturer Unplug When Unused For Long Periods Of Time Refer All Servicing To Qualified Personnel Only No User Serviceable Parts Inside FAILU...
Страница 3: ...Rack Reset All Racks 18 Checkboxes 18 Create Debug File 18 Auto Load Last Setup File On Startup 18 Auto Restore Previous Setup On Startup 18 Pro Tools Control Setup 20 AD DA FireWire Expansion Board...
Страница 4: ...t The unit always powers up with all settings levels and states as they were at power down An optional Digital module provides a Firewire AES interface with four channels of A D and D A conversion to...
Страница 5: ...rface and not the AES If a Firewire connection is not detected then the 4081 will presume the audio is coming in via the AES IN OUT 25 way D type connector The optional expansion module has 4 DA AD co...
Страница 6: ...d unlit for LINE Swaps the incoming phase of the Mic or Line signal INS This selects the source for the A D in the FireWire expansion module if fitted When illuminated allows an external Insert Pre th...
Страница 7: ...ring Again these can run at up to 192kHz true stereo single wire 192kHz operation Control of the sample frequency and syncronisation source in standalone mode is done entirely through the front panel...
Страница 8: ...e when AES EBU sync is selected If the green led is flashing it means that the AES EBU source is running at a different sample rate to the 4081 Change the sample rate of the 4081 using the and buttons...
Страница 9: ...puts to the DAC outputs as these are reserved for the FireWire Setting the Sync source in FireWire mode In FireWire mode selection of the sync source and sample rate is done entirely from the DAW appl...
Страница 10: ...ce is running at a different sample rate to that selected on the 4081 Change the sample rate of the 4081 from the DAW application until the green AES EBU led is solid or change the sample rate of the...
Страница 11: ...d to Once it has downloaded double click the file to run and install it The Windows operating system will be determined as will the correct driver for your system A Windows CMD screen will show the in...
Страница 12: ...procedure will terminate here Click Next A summary of the software development will be shown Click Next Select the location to install the software to It is recommended you leave this set to the defa...
Страница 13: ...ish to launch the programme at this point select Launch 4081 Remote Mic Pre Amp Controller option before clicking Finish and the programme will then open Click Finish The first time the software is op...
Страница 14: ...ure is still the same At any point in the install you can return to the previous screen by click Back Before installing this software please connect your 4081 via USB and power the unit up Double clic...
Страница 15: ...for you Click Continue Click Install to continue and the software will start to be installed Once installed a confirmation screen will report it has been installed successfully Click Close Once instal...
Страница 16: ...nt panels will be updated with any changes made on screen If you wish to enable the metering on the Main Screen ensure the Enable Meters tickbox is checked If this is left unticked the only indication...
Страница 17: ...version of firmware is displayed next to the first four units To test the ID of each unit click the relevant Test button This will flash all of the Phase buttons once on that particular unit and you...
Страница 18: ...n all operational aspects this screen is identical to the full size screen except for Click or to step through the racks in numerical order the display will reflect which rack is being displayed and w...
Страница 19: ...ve a mic suffix Load Preset Once selected opens a standard Windows Load dialogue so that the files created above can be loaded back to the units The settings are global ie there is nothing to set or s...
Страница 20: ...his will appear either as an icon on the desktop or can be accessed from the Applications folder On the main page click Setup and the General screen will open At the top of the screen click MIDI In bo...
Страница 21: ...tartup option will cause the last saved or last loaded system setup to be reloaded when the software is next started When controlling the 4081 from Pro Tools it is advisable to turn this option off On...
Страница 22: ...r of pliers Fitting Instructions Ensure that the 4081 unit is powered down and remove the 48v power cable from the 4081 Remove the expansion blanking panel from the back of the 4081 and also the lid R...
Страница 23: ...he FireWire board to the posts Connect the 2 pin power cable between J16 of the expansion board and the power distribution board mounted on the front panel of the unit as shown below The power connect...
Страница 24: ...king the Setup button and then checking the version against each unit Where you have more than one unit connected via the USB RS485 chain it is important that all units are running the same versions o...
Страница 25: ...as Insert Sends The Output is Post the Gain control Pin outs as above Power input 48 volts 8 pin connector This connector is polarised so can only be connected one way INS IN LINE OUT A 25 pin D sub c...
Страница 26: ...X 2 3 1 screen 1 AES 1 contains data for channels 1 L and 2 R from the 4081 AES 2 contains data for channels 3 L and 4 R from the 4081 On the AES Ins Outs 25 way connector on the rear of the 4081 a nu...
Страница 27: ...ld have a unique ID as shown left The procedure for setting these IDs is described on page 29 Cable Specification The RS 422 specification recommends 24AWG twisted pair cable with a shunt capacitance...
Страница 28: ...creen 1 Male XLR 4 14 Line Out 4 hot 2 8 1 Line Out 4 cold 3 2 screen 1 Female XLR 1 12 Insert IN 1 hot 2 1 24 Insert IN 1 cold 3 25 screen 1 Female XLR 2 23 Insert IN 2 hot 2 2 10 Insert IN 2 cold 3...
Страница 29: ...switch block labelled SW2 inside the unit with the front of the unit to the left this switch block is just above a white programming connector With this switch in the down position the unit will have...
Страница 30: ...pe 1A 20mm x 5mm Location FS1 Mains Power The power supply is universal input type and therefore no mains operating voltage setting is required Technical Earth When switched on internally connects zer...
Страница 31: ...4081 User Manual Issue 3 Dimensions single unit 31...
Страница 32: ...eserve the right to alter specifications without notice but with due regard to all current legislation Disclaimer The information in this manual has been carefully checked and is believed to be accura...